SECTION 7 DHL HEATLESS REGENERATIVE DRYER
45
Dryer does not
perform the
switching cycles.
Solenoid valve PVA and/or PVB are never activated - see specific point.
Inlet and/or outlet shuttle spool valve is blocked – carry out maintenance
operations.
All the inlet air is
discharged through
the silencers.
The dryer does not perform the switching cycles—see specific point.
The solenoid valve PVA and/or PVB is blocked—open and clean it.
The membrane of solenoid valve PVA and/or PVB is broken—carry out mainte-
nance operations.
The SHDC-2100 Electronic controller always supplies solenoid valve PVA and/or
PVB – verify the electric wiring and if necessary replace.
The cycle times on the SHDC-2100 electronic controller have been changed—
restore nominal conditions.
Regeneration nozzle is clogged—open and clean it.
Liquid comes out of
the silencers.
Humidity in outlet air – see specific point.
LED
“HI PDP” of the
SHDC-2100 device
flashes or is on.
The probe of the DewPoint Meter (optional) detects a high DewPoint, for one of the following
reasons:
Humidity at dryer outlet—see specific point.
The air flow adjuster setting has been changed (see Section 6.14)—reset
nominal value.
The selector valve of the operating tower (see Section 6.14) is blocked—
replace it.
Verify the electric connection of the probe.
The probe is not calibrated—contact the dealer.
The probe is broken—replace it.
There is an air leak on the pipes and/or joints that connect the equip-
ment— verify the connections and replace the damaged parts.
A pipe or a joint which connects the equipment is clogged—replace it.
The LED
“FAIL TO SWITCH”
of the SHDC-2100
device flashes or is
on.
The pressureswitches(optional)forthe“FAILTOSWITCH”function,show an anomalous condi-
tions during the tower switching process, for one of the following reasons:
The dryer does not run the switching cycle – see specific point.
All the inlet air is purged through the silencers – see specific point.
The solenoid valve PVA and/or PVB is never enabled – see specific point.
The pressure switches are not calibrated – reset the default settings (see
Section 6.17).
There is an air leak on the pipes and/or joints that connect the equipment
–verify the connections and replace the damaged parts.
A pipe or a joint which connects the equipment is clogged – replace it.
PROBLEM POSSIBLE CAUSE - SUGGESTED ACTION