USER/SERVICE MANUAL
DESICCANT HEATLESS REGENERATIVE
COMPRESSED AIR DRYERS
DHL-80 TO DHL-5000
PART NUMBER:
KEEP FOR
FUTURE
REFERENCE
©
SULLAIR CORPORATION
02250195-403 R00
The information in this manual is current
as of its publication date, and applies to
compressor serial number:
and all subsequent serial numbers.
SHDIDFAA-0001

Other manuals for Sullair DHL-1000

Questions and Answers

  • C
    Casey GilbertAug 14, 2025
    How to check the clogging state of the filters in my Sullair Dehumidifier?
    • B
      Beverly BeckerAug 14, 2025
      To check the clogging state of the filters, read the differential pressure gauge installed on your Sullair Dehumidifier.
  • M
    Michael JonesAug 21, 2025
    What to do if the alarm light is ON on my Sullair Dehumidifier?
    • H
      hollowaysharonAug 21, 2025
      If the alarm light is on, check the display to see if the filter needs replacement. If differential pressure switches are installed on the filters, replace the filter elements. If there are no switches, and it has been 6000 hours, replace the element. A high dew point alarm indicates that the dew point at the outlet exceeds 33 degrees F; in this case, refer to the troubleshooting steps for 'Moisture in the Outlet Air'. If an optional pressure switch in either the right or left tower has failed, identify the unpressurized tower via the screen, follow steps 2, 3, and 4, and replace the faulty pressure switch if necessary.
  • A
    Ana SimmonsAug 25, 2025
    What to do if my Sullair DHL-1000 Dehumidifier dryer towers do not switch correctly?
    • K
      Kenneth JonesAug 26, 2025
      If the dryer towers on your Sullair Dehumidifier aren't switching correctly, the issue might stem from the solenoid valves PVA and/or PVB not activating. Refer to the specific troubleshooting steps for that problem. Alternatively, the inlet and/or outlet valve could be blocked, or the inlet solenoid might not be working; perform necessary maintenance. Also, inspect the purge exhaust mufflers for cleanliness and replace them if needed.
  • M
    Morgan RodriguezAug 29, 2025
    What to do if all the inlet air is discharged through the purge exhaust mufflers of my Sullair DHL-1000?
    • K
      Kristina ChavezAug 29, 2025
      If all the inlet air is being discharged through the purge exhaust mufflers of your Sullair Dehumidifier, it could be due to several reasons. First, the dryer may not be performing the switching cycles correctly, so refer to Step 2. The purge solenoid valve PVA and/or PVB might be blocked, requiring you to open and clean it. Another possibility is that the SHDC-2300 electronic controller is constantly supplying solenoid valve PVA and/or PVB; in this case, check the wiring and replace it if necessary. If the cycle times on the SHDC-2300 electronic controller have been changed, restore them to their original settings. Lastly, the regeneration nozzle could be clogged, so open and clean it.
  • D
    David GarciaSep 1, 2025
    Why are purge solenoid valves never activated in my Sullair Dehumidifier?
    • S
      Scott RodriguezSep 1, 2025
      If the purge solenoid valves in your Sullair Dehumidifier are never activated, check the electrical supply or on/off switch for failures and verify the electrical wiring. The valve may also be blocked, requiring you to open and clean it. If the solenoid valve has failed, replace it.
  • O
    okirbySep 5, 2025
    What does it mean if there is liquid at the purge exhaust mufflers of my Sullair Dehumidifier?
    • B
      Benjamin PenaSep 5, 2025
      If you notice liquid at the purge exhaust mufflers of your Sullair Dehumidifier, it indicates humidity in the outlet air. Refer to the troubleshooting steps for 'Moisture in the Outlet Air' to resolve the issue.
  • C
    christopheryoungSep 9, 2025
    What causes Hi-Dew point in Sullair Dehumidifier and how to resolve it?
    • P
      Pamela LiSep 9, 2025
      A high dew point in your Sullair Dehumidifier can be caused by several factors. It may indicate humidity at the dryer outlet, in which case you should refer to the troubleshooting steps for 'Moisture in the Outlet Air'. Ensure a constant airflow through the dew point measuring cell if the dew point meter has been changed. A blocked shuttle valve supplying air to the dew point meter should be cleaned to ensure dry air flows from the tower during drying. If the probe is broken, replace it. Air leaks in pipes or joints connecting the equipment should be verified and damaged parts replaced. Finally, a clogged pipe or joint connecting the equipment needs replacement.
  • C
    campbellmitchellNov 16, 2025
    Why is there moisture in the outlet air of my Sullair Dehumidifier?
    • J
      Jill SalinasNov 16, 2025
      Moisture in the outlet air of your Sullair Dehumidifier can occur for several reasons. It could be that the dryer is switched off—simply turn it on. If the dryer was recently commissioned, the adsorption material may contain humidity; run the dryer at about 50% flow for at least two days and check its operation. Other potential causes include the inlet air being too hot (restore to nominal conditions), the inlet pressure being too low (verify the correct regeneration nozzle for your dryer's rated pressure), or the inlet airflow exceeding the dryer's rate (reduce the flow). Also, check if the inlet filter isn't draining condensate properly or if its electronic timer isn't adjusted correctly (reduce the drain pause timer). A pressure gauge reading higher than zero on the regenerating tower, ...

Summary

Safety Information and Guidelines

Safety Information

End user and operator must observe National, State, and Local safety regulations.

Definition of Safety Symbols

Key Safety Precautions

Warnings

Lists critical warnings and precautions for operating the equipment.

Proper Use of the Dryer

Defines authorized use and conditions for operating the dryer.

Instructions for Pressure Equipment Use

Installation Procedures

Installation Layout and Factors

Installation Procedures and Conditions

Dryer Startup Procedures

Preliminary Operation Checks

Steps to verify operating parameters and dryer integrity before initial start-up.

First Startup Guide

Step-by-step guide for performing the initial startup procedure.

Operation and Switching Off

Technical Specifications Overview

Technical Description of Dryer

Control Panel Interface

Describes the interface between the dryer and the operator, including components.

Description of Dryer Operation

Explains how the heatless regenerative adsorption dryer functions.

Dryer Operation and Settings

Dryer Operation

Explains how the desiccant material in the towers adsorbs moisture.

Cycle Description

Control Panel Details

Operating Modes Explained

Alarm and Indicator Descriptions

Operation Configuration Settings

Device Power and Configuration Switches

DIP Switch Parameter Settings

Operating Cycles: FIX Mode

DPD Operating Cycle

DPD Cycle Behavior Explained

Test Mode Functionality

Maintenance, Fuses, and Dewpoint Meter

Fail to Switch Alarm Pressure Switches

Calibration Pressures for Switches

Maintenance, Troubleshooting, Spares, Dismantling

Troubleshooting Common Problems

Troubleshooting Common Issues

Comprehensive Spare Parts List

Detailed Spare Parts Information