OIL WATER SEPARATOR SECTION 2
14
2.11 CHECKING OF
DISCHARGING WATER
(see also Test & Service Log)
A test sample should be taken from the test valve (8).
The water must be clean and clear. If the water is
dirty the filters should be changed.
WEEKLY
Take a sample out of the test-valve
Optical check (see also Test & Service
Log)
Check with oil-test-paper (see also Test &
Service Log)
SEMIANNUAL
Replace filters and clean tank as needed
ANNUAL
Replace filters (min. once a year, if necces-
sary more often!)
Send a sample of the filtered condensate
to a certified laboratory for evaluation.
The results from the laboratory should be noted in
your “Test & Service Log”. You should also note
when the filters were changed and when the
maintenance work was carried out.
2.12 DISPOSAL
The saturated filters have to be disposed of
according local EPA regulations. For details contact
a disposal company in your area.