12.3 Replacing the Control Board (SRC-250 to 1000)
Open the electrical box.
Remove the white connector containing the electrical supply & digital inputs & outputs.
Disconnect the temperature sensor wires.
Disconnect the level sensor (SRC-400 to 1000 ONLY) Pull firmly on the connector, being
careful not to damage it.
Electrical supply &
digital input & output
connections
Level sensor
connection
Tem
p
erature senso
r
connections
Unscrew the six screws holding the board in place.
Replace the old board with the new one.
Reinstall the temperature sensors, wires in the same locations.
12.4 Replacing the Drain Valve
Loosen the 3 piece union.
Unscrew the electrical connector.
Remove the fixing nut.
Remove the old coil and install the new one.
Replace the fixing nut.
Reattach the electrical connector.
Tighten the 3 piece union.