Section 7
ILLUSTRATIONS AND PARTS LIST
77
7.14 ELECTRO-PNEUMATIC CONTROL SYSTEM - STANDARD CONTROL
key part
number description number quantity
1 spacer, block 2” x 3” x .38”thk 02250117-602 4
2 valve, solenoid 2wno 3/8” 150#vac n4 (I) 02250125-538 1
3 switch, pressure n.o. 10psi 250017-992 2
4 grip, cord for so 12/4 st 3/4” 250018-497 1
5 support, starter&clr 200hp 250022-657 2
6 elbow, 90deg m swvl 1/4t x 1/8npt 250025-849 3
7 elbow, 90deg m swvl 1/4t x 1/4 npt 250025-850 1
8 switch, press 12.5psi fixed nc 250025-975 1
9 plug, hole n4 1/2” cond 409918-002 4
10 nut, hex pltd 3/8-16 825206-337 4
11 capscrew,hex gr5 3/8-16 x 1 1/2 829106-150 4
12 capscrew,hex gr5 1/2-13 x 1 1/2 829108-150 4
13 washer, spr lock reg pltd 3/8 837806-094 4
14 washer, spr lock reg pltd 1/2 837808-125 4
15 washer, pl-b reg pltd 3/8 838206-071 8
16 washer, pl-b reg pltd 1/2 838208-112 4
17 elbow, 90deg lq-tite 1/2 846600-050 1
18 nipple, chase cond 1/2 847815-050 1
19 bushing, red pltd 3/8 x 1/4 867101-010 1
20 starter, vs n4 (II) -1
(I) For maintenance on solenoid valve no. 02250125-538, order repair kit no. 02250160-750, and replace-
ment coil no. 02250125-858.
(II) Starter may vary in accordance with machine package. Consult factory to determine proper part num-
ber.
PLEASE NOTE: WHEN ORDERING PARTS, ALWAYS INDICATE SERIAL NUMBER OF VACUUM
PNEUMATIC LEGEND
A OIL PRESSURE
B SUMP PRESSURE
C FROM SULLICON CONTROL PORT
D FROM WATER COOLER (WATER-
COOLED MACHINES ONLY)
ELECTRICAL LEGEND
1 A/C COOLING FAN (OR WC CNPY FAN)
2 TEMPERATURE SWITCH
3 OIL PRESSURE SWITCH
4 SUMP PRESSURE SWITCH
5 WATER PRESSURE SWITCH (WC
MACHINES ONLY)