What to do if my Sullivan-Palatek Air Compressor won't start?
- DDaniel JonesAug 3, 2025
If your Sullivan-Palatek Air Compressor won't start, here are some possible causes and solutions: * The main disconnect might be open. In this case, close the switch. * Line fuse(s) might be blown. Replace the fuse(s). * The control circuit breaker could be tripped. Reset the circuit breaker. * The motor starter overload might be tripped. Reset it. If the problem continues, check the sizing and adjustment of the overload and ensure the motor starter contacts are functioning correctly. * There might be low incoming line voltage. Check the voltage, and if it's low, consult your power company. * There might be a unit lock-up. It could be filled with oil due to a leaking inlet valve (replace the inlet valve) or due to unit failure (replace the unit).