4
Operation
LED Operator Screen Structure
Conveyor Application
No. Parameter Name Default Setting
A1-02 Control Method Selection 0 : V/f Control
C1-01 Acceleration Time 1 3.0 s
C1-02 Deceleration Time 1 3.0 s
C6-01 Drive Duty Selection (ND/HD) 0 : Heavy Duty (HD)
L3-04 Stall Prevention Selection during Deceleration 1 : Enabled
1
2
3
4
DRV
5
6
7
8
9
10
11
Tum the power on
Drive Condition Setting
• Local Mode
• Frequency Reference Setting
Forward/Reverse
Output Frequency
Output Current
Output Volage
Monitor Display
Verify Mode
Set Up Mode
Parameter Setting Mode
Auto-Tuning Mode
Return Frequency Reference
Setting
Flashing
Flashing
Flashing
When the parameter change is possible, display is flashing.
Step DisplayKey Operation
Step DisplayKey Operation
Step DisplayKey Operation
Step DisplayKey Operation
< Frequency Reference Setting >
Frequency Reference
Writing of Frequency
Reference
After “End” display
Green Light
Monitor Mode : Condition monitor, Alarm and Alarm history
Select the monitor item
Monitor U1-O1
(Frequency Reference)
Select another monitor item
Push
Push
Verify Mode :
Check the edited parameter.
Check the value of the
edited parameter.
LO Light
Return to the verify menu.
After pressing one more ESC Key, return to the initial display.
The Verify Menu lists edited parameters from the Programming
Mode or as a result of Auto-Tuning.
Drive Mode :
Structure for LED Operator
Monitor the operation status of the drive
(Frequency reference, Output frequency, Output current, Output voltage, etc.).
Return the monitor mode
display
The application Presets function is applicable.
The parameters are changed to the optimum value for each application.
Setup Mode