TECHNICAL INSTRUCTION Sumitomo Heavy Industries, Ltd.
CSW-71C 26
3-1 PERIODICAL MAINTENANCE
INSTALLING NEW ADSORBER
1 Set a new Adsorber.
2 Secure the Adsorber to the base panel of the Compressor Unit by tightened Nut and Washer.
Tightening Torque: 14.5 Nm
3 Secure the Adsorber to Rear Panel by tightening Nut.
Tightening Torque: 23 Nm
4 Connect the Adsorber Self-Sealing Coupling.
Tightening Torque: 50 Nm
5 Sprinkle “Liquid Leak Detector” on the Flex line connecting coupling, in case the bubbling is found,
tighten the connecting coupling again and re-check the leakage.
Ensure that the pressure gauge indication is specified value for the type of Cold Head. Charge
the helium gas, in case of low pressure indicating.
6 Reinstall the panels and secure them by tightening the screws.