Built Better To Last Longer
Residential
Central Heat Recovery Ventilator
Product Specications
and
Installation and Trouble Shooting Guide
Proventor II Series
Model
SHRV150DM
APPLICATION WARNING
It is always important to assess how the
operation of any Heat Recovery Ventilator
(HRV) may interact with vented combustion
equipment (i.e. gas furnaces, oil furnaces,
wood stoves, replaces. etc.)
Never install an HRV in a situation where
it’s normal operation, lack of operation, or
partial failure may result in the back drafting
on vented combustion equipment such as
water heaters, furnaces and replaces
DO NOT ATTEMPT INSTALLING THIS HRV WITHOUT FIRST
READING THIS ENTIRE MANUAL
Summeraire Mfg.
Peterborough, Ontario,
Canada, K9J 6X6

Questions and Answers

  • S
    sherrysilvaJul 31, 2025
    Why is there persistent condensation on my SummerAire Fan windows?
    • M
      Michael GonzalesJul 31, 2025
      If you notice persistent condensation on your windows when using the SummerAire Fan, it might be due to a few reasons. First, the dehumidistat settings may need adjustment to achieve the correct relative humidity (RH) reading. Try setting it lower and verify its functionality; if it's faulty, replace it. Also, ensure that the HRV operates continuously and consider increasing the fan speed to improve ventilation. The system should be balanced. A broken damper blade assembly can also cause this issue, requiring replacement. Lastly, a failed main control board could be the culprit, so replace it and inspect the connection between the motor shaft and damper, as the coupling might be loose.

Summary

Application Warning

Product Specifications and Performance Ratings

Ventilation Performance Data

Tables detailing net supply, gross air flow, and power ratings under various static pressures.

Model Select Switch Configuration

Fan Curve Selection

Air Flow Balancing Procedure

LED Status and Flash Codes

Wiring Diagram and Connections

Troubleshooting Guide

Persistent Condensation & Defrost Issues

Solutions for condensation on windows and defrost mode failures.

Humidity Level Issues

Addresses low humidity levels and potential causes or solutions.

Control Function Troubleshooting

Unit Not Working & Motor Issues

Troubleshooting for units not working, damper motors, and blower motors.

Dehumidistat & Noise Issues

Diagnosing dehumidistat failures and resolving annoying HRV noise.

SummerAire Proventor II Series Specifications

General IconGeneral
BrandSummerAire
ModelProventor II Series
CategoryFan
LanguageEnglish