Battery type selector
Switch setting Description Boost / Vdc Float / Vdc
0 Charger Off
1 Gel USA 14.0 13.7
2 AGM 1 14.1 13.4
3 AGM 2 14.6 13.7
4 Sealed lead acid 14.4 13.6
5 Gel EURO 14.4 13.8
6 Open lead acid 14.8 13.3
7 Calcium 15.1 13.6
8 De-sulphation 15.5 (4 Hours then Off)
9 Not used
12Vdc Mode (*2 for 24Vdc ; *4 for 48Vdc)
De-sulphation
The de-sulphation cycle on switch position 8 is marked in red because this is a very dangerous setting if you
do not know what you are doing. Before ever attempting to use this cycle you must clearly understand what
it does and when and how you would use it.
What causes sulphation? This can occur with infrequent use of the batteries(nor), or if the batteries have
been left discharged so low that they will not accept a charge. This cycle is a very high voltage charge cycle
designed to try to break down the sulphated crust that is preventing the plates taking a charge and thus allow
the plates to clean up and so accept charge once again.
Charging depleted batteries
The APVseries inverter allows start up and through power with depleted batteries.