EasyManua.ls Logo

Sun Gold Power SPH8K48SP - User Manual

Sun Gold Power SPH8K48SP
41 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Sun Gold Power Co., LtD www.sungoldpower.com
All-in-one solar charge inverter V3.0 1
USER MANUAL
All-in-one solar charge inverter
SPH8K48SP
SPH10K48SP

Questions and Answers

  • K
    Kevin KelleyAug 14, 2025
    How to fix Sun Gold Power Inverter screen with no display?
    • N
      Nathaniel WoodAug 14, 2025
      If your Sun Gold Power Inverter screen isn't displaying anything, it could be due to a lack of power input or because it's in sleep mode. Try closing the circuit breaker and making sure the rocker switch is turned on. If it's in sleep mode, push any button on the panel to wake it up.
  • L
    lauriemillerAug 17, 2025
    What to do if Sun Gold Power Inverter says battery not connected?
    • C
      Christina SanfordAug 17, 2025
      If your Sun Gold Power Inverter indicates that the battery is not connected, there are a few things to check: * Make sure the battery is securely connected. * Verify that the battery's circuit breaker is closed. * If you're using a Li-ion battery, ensure its Battery Management System (BMS) is communicating correctly.
  • Y
    Yolanda OlsonAug 21, 2025
    Why is my Sun Gold Power SPH8K48SP Inverter showing a bypass overload?
    • S
      Sarah WilsonAug 21, 2025
      A bypass overload on your Sun Gold Power Inverter, detected by software, indicates that the output power or current has exceeded its limit for a certain time. To resolve this, reduce the power being drawn by the connected devices and then restart the inverter. For more details, refer to item 11 of the protection features.
  • M
    Mrs. Frances PattersonAug 25, 2025
    What to do if Sun Gold Power Inverter shows battery over-voltage when charging?
    • Q
      qcoleAug 25, 2025
      If your Sun Gold Power Inverter displays a battery over-voltage error during charging, the battery voltage is too high. Power off the inverter and restart it. Check if the battery voltage exceeds the allowed limit. If it does, you will need to discharge the battery until its voltage drops below the over-voltage recovery point.
  • C
    Caitlin CarrollAug 27, 2025
    How to fix Sun Gold Power SPH8K48SP Inverter battery over-discharge?
    • S
      Scott KingAug 27, 2025
      If your Sun Gold Power Inverter is showing a battery over-discharge error, it means the battery voltage is lower than the value set in parameter [12]. You can manually reset the inverter by powering it off and then restarting it. Alternatively, the inverter will automatically reset once the battery is charged to a voltage higher than the value set in parameter [35].
  • T
    Thomas GrossAug 30, 2025
    Why does my Sun Gold Power Inverter show battery under-voltage?
    • B
      balljonathanAug 31, 2025
      Your Sun Gold Power Inverter is displaying a battery under-voltage error because the battery voltage is lower than the value specified in parameter [14]. To resolve this, charge the battery until its voltage exceeds the value set in parameter [14].
  • M
    mary96Sep 3, 2025
    How to resolve a utility input phase fault on a Sun Gold Power SPH8K48SP Inverter?
    • M
      Matthew WebbSep 3, 2025
      A utility input phase fault on your Sun Gold Power Inverter means the AC input phase doesn't match the AC output phase. To fix this, make sure the phase of the AC input is the same as the phase of the AC output. For example, if the output is in split-phase mode, the input must also be in split-phase.
  • A
    Albert MooreSep 6, 2025
    What causes AC Input relay short circuit in Sun Gold Power SPH8K48SP Inverter?
    • D
      Denise StokesSep 6, 2025
      An AC input relay short circuit in your Sun Gold Power Inverter is caused by the relay for the AC input sticking. Power off the inverter and restart it. If the fault happens again, contact after-sales service to repair the machine.
  • J
    Jennifer PerrySep 9, 2025
    What to do if Sun Gold Power Inverter fan fails?
    • J
      John SotoSep 9, 2025
      If your Sun Gold Power Inverter's fan has failed, which is detected by hardware for 3 seconds, switch off the inverter and manually toggle the fan to check if any foreign objects are blocking it.

Summary

Safety

How to Use This Manual

Provides important information, guidelines, operation, and maintenance for the products.

Symbols in this Manual

Explains symbols used for warnings, cautions, and notices in the manual.

Safety Instructions

Contains critical safety instructions for installation, operation, and maintenance.

Production Instructions

Instructions

Introduces the SPH series inverter, its control algorithm, and features.

Features

Lists key features like battery support, output modes, protections, and communication.

System Connection Diagram

Illustrates the system application scenario and components of the inverter setup.

Production Overview

Details the physical layout and identification of ports and components on the inverter.

Installation

Select the Mount Location

Provides guidelines for choosing a suitable and safe installation site for the inverter.

Mount the Inverter

Details the process of physically mounting the inverter using specified dimensions and hardware.

Remove Terminal Cover and Insect Screen

Instructions on removing covers for access and cleaning the insect screen.

Connection

Connection Overview

Explains split-phase and single-phase AC output modes and voltage configurations.

Cable and Circuit Breaker Requirements

Specifies cable diameters and circuit breaker ratings for PV, AC, and battery connections.

AC Input and Output Connection

Details how to connect AC inputs and outputs correctly, including wire order.

Battery Connection

Explains the procedure for connecting the positive and negative battery terminals.

PV Connection

Guides on connecting the positive and negative wires of PV strings to the inverter.

Dry Contact Connection

Instructions for connecting the dry contact port for external control signals.

Grounding Connection

Details the importance and method of proper grounding for safety and performance.

Final Assembly

Instructions on installing the terminal protection cover after wiring is complete.

Start Up the Inverter

Step-by-step guide for powering on and activating the inverter.

Operation

Operation and Display Panel

Describes the LCD screen, LED indicators, and touchable keys for operation.

Setting

Details the process of navigating the setup menu and adjusting parameters.

AC Output Mode

Explains different AC output power source priority modes (e.g., Utility, Solar, Battery).

Battery Charging Mode

Describes various modes for charging the battery (e.g., Hybrid, Utility Priority, Solar Priority).

Time-Slot Charging;Discharging Function

Enables setting specific time slots for charging and discharging based on tariffs.

Battery Parameter

Lists detailed parameters for various battery types, including lead-acid.

Communication

Overview

Introduces the various communication ports available for data transfer and control.

USB-B Port

Details the use of the USB-B port for reading and modifying device parameters.

WIFI Port

Explains connecting to the Wi-Fi/GPRS data acquisition module for mobile app monitoring.

RS485;CAN Port

Describes connecting to the BMS of Li-ion batteries via RS485/CAN protocols.

Dry Contact

Explains the functions and connections of the dry contact port for external control.

Fault and Remedy

Fault Code

Lists and explains various fault codes, their meaning, and impact on outputs.

Troubleshooting

Provides causality and remedies for common system issues and fault codes.

Protection and Maintenance

Protection Features

Details the inverter's built-in protective functions against various electrical and thermal faults.

Maintenance

Recommends regular checks for optimal performance, safety, and longevity.

Datasheet

Inverter Output Specifications

Technical specifications for inverter output power, voltage, waveform, and load capacity.

Battery Specifications

Parameters for battery type, rated voltage, charging currents, and hybrid charging.

PV Input Specifications

Details on MPP trackers, maximum PV array power, input current, and voltage limits.

Mains;Generator Input Specifications

Input voltage and frequency ranges for mains and generator power sources.

Efficiency

Information on MPPT tracking efficiency and maximum battery inverter efficiency.

General Specifications

Dimensions and Weight

Physical size, dimensions, and weight of the inverter unit.

Operating Temperature and Noise

Environmental operating conditions, derating temperatures, and noise level.

Warranty and Certification

Information on product warranty period and relevant safety/EMC certifications.

Sun Gold Power SPH8K48SP Specifications

General IconGeneral
ModelSPH8K48SP
CategoryInverter
Rated Power8000W
Peak Power16000W
Input Voltage48V DC
Frequency50Hz/60Hz
WaveformPure Sine Wave
CoolingForced Air Cooling
Operating Temperature-10°C to 50°C
Protection FeaturesOverload, Short Circuit, Over Temperature