5-16 Sun StorEdge 3000 Family FRU Installation Guide • May 2004
b. Reset the RAID Controllers: From the Main Menu, choose “system Functions,”
then “Reset controller.” Confirm Yes when prompted.
c. This procedure is now complete. Proceed with Step 20.
19. If this array is NOT being used by clustered hosts, perform these steps:
a. On the firmware main menu, choose “view and edit Configuration parameters,”
then choose “Controller Parameters,” and press Return.
b. From the Controller Parameters menu, choose “Controller Unique Identifier
<hex>” and press Return.
c. Type in the value 0 and press Return (to automatically read the chassis serial
number from the midplane).
The value 0 is immediately replaced with the hex value of the chassis serial
number.
d. To implement the revised parameter value, choose “system Functions” on the
Main Menu, choose “Reset Controller” and press Return. Confirm Yes when
prompted.
20. Connect the array to hosts according to the configuration identified in Step 5 and
Step 6. The chassis replacement is now complete.