Questions and Answers

  • N
    Nicholas BoydAug 11, 2025
    What to do if the red triangle flashes on my Sundstrom Respiratory Product?
    • C
      chris36Aug 11, 2025
      If the red triangle flashes on the display and the fan sounds and vibrates on your Sundstrom Respiratory Product, it's likely due to clogged filters. Try changing the pre-filters and particle filters. Also, check the hose to ensure air flows freely and that it's in good condition. Finally, verify that the exhalation valves with membranes are fitted to your head top.
  • C
    Cynthia WillisAug 17, 2025
    How to troubleshoot Sundstrom SR580 fan unit that fails to start?
    • P
      Patricia MasonAug 17, 2025
      If the fan unit of your Sundstrom Respiratory Product fails to start, first, recharge the battery. If that doesn't work, check for fan-battery contact problems by bending, adjusting, or cleaning the battery terminals and ensuring there are two terminals. Also, check the contact rivets on the fan. If the battery is faulty, replace it with a new one and measure the voltage, which should be 13 – 17 V. Inspect the charger for dirt on the contacts and consider replacing it. If none of these steps work, the fan motor/electronic fault may be the issue, and you should send the fan unit for repair.
  • J
    Joshua LongAug 25, 2025
    What to do if the red triangle flashes on Sundstrom SR580?
    • K
      Kevin RhodesAug 25, 2025
      If the red triangle flashes on the display and the fan sounds and vibrates on your Sundstrom Respiratory Product, it's likely due to clogged filters, a damaged hose, or issues with the valves. Try these steps: * Change the pre-filters. * Change the particulate filters. * Check that the air flows freely through the hose and that the hose is in good condition. * Ensure that the exhalation valves with membranes are fitted to your human interface.
  • D
    Devon McdowellAug 29, 2025
    How to fix Sundstrom Respiratory Product when the fan fails to start?
    • T
      Travis MillerAug 29, 2025
      If the fan fails to start on your Sundstrom Respiratory Product, there are several potential causes: 1. The battery may be discharged: Recharge the battery. 2. There may be fan-battery contact problems: Bend, adjust, or clean the battery terminals. Ensure there are two terminals and check the contact rivets on the fan. 3. The battery could be faulty: Try a new battery or test another battery. Measure the voltage, which should be 13 – 17 V. 4. The charger might be faulty: Visually inspect the charger and battery contacts for dirt. You may need a new battery charger. 5. There may be a fan motor/electronic fault: In this case, send the fan away for repair.
  • L
    lobrienSep 4, 2025
    Why Sundstrom SR580 Respiratory Product fan does not run smoothly?
    • P
      ptuckerSep 4, 2025
      If the fan on your Sundstrom Respiratory Product isn't running smoothly, it might be due to a clogged filter, an incorrect filter combination, or the absence of filters. Check that there are filters in the fan unit and that they are of the same type, such as SR 532 OV/SD/CL/HC/HF + SR 510 P100/HE.