Why does my Sundyne LMV-313 have insufficient total head?
- CCasey EdwardsAug 18, 2025
If your Sundyne Water Pump has insufficient total head, several factors could be responsible. The flow might be too high or too low, so check the total head and flow rate against the performance curve, and increase through-flow rate or bypass part of pump discharge to supply tank if the flow is too low. Ensure the driver shaft rotation direction matches the arrow on the pump casing, noting that the impeller and driver rotate in the same direction. Also, the NPSH might be lower than required, so refer to the solutions listed under “No flow, no pressure at start-up”. For high flow models (313/333/343/348), excess clearance at the impeller face could be the issue, requiring disassembly and a clearance check.