21
+1 (855) 251-1649
sunfireheaters.com
BURNER SERVICE:
Do not attempt to handle burner components unless the unit has been unplugged and cooled
completely. Components can be hot and could cause severe personal injury.
The burner assembly should be serviced seasonally, at a minimum, or whenever excess smoke is present or a
clog or poor fuel quality is suspected. For inspection or service, the nozzle subassembly will need to be removed
from the heater and the flame sensor, igniter electrode, and combustion chamber should be inspected.
TO SERVICE THE BURNER ASSEMBLY:
1. Use a Phillips-head screwdriver to remove the four (4) screws securing the burner cover to the unit.
Then, remove the burner cover.
2. Use a Phillips-head screwdriver to remove the screw securing the square access door closed.
Then, swing the door down.
3. Inspect the flame sensor for dirt or damage. Use a soft, damp rag or cotton swab to clean the sensor.
If the flame sensor shows signs of damage,
troubleshoot the unit to determine and
correct the cause and replace the flame
sensor before resuming operation of the unit.
Contact SunFire technical service for
assistance.
REMOVE BURNER COVER SCREWS
REMOVE BURNER COVER
REMOVE ACCESS COVER SCREW OPEN ACCESS COVER
INSPECT FLAME SENSOR