4.2.4 Installation Clearance Requirements
Reserve enough clearance around the inverter to ensure sufficient space for heat
dissipation.
In case of multiple inverters, reserve specific clearance between the inverters.
4 Mechanical Mounting User Manual

Table of Contents

Other manuals for Sungrow SG15KTL-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG15KTL-M and is the answer not in the manual?

Sungrow SG15KTL-M Specifications

General IconGeneral
Max. DC Input Voltage1100 V
Input Voltage Range200 V - 1000 V
MPPT Voltage Range200 V - 1000 V
Number of MPPT2
Max. DC Input Current per MPPT26 A
AC Voltage Range310 V - 480 V
Rated Grid Frequency50 Hz / 60 Hz
Power Factor at Rated Power> 0.99
THDi< 3%
Protection ClassIP65
Rated Output Power15 kW
Max. AC Apparent Power16.5 kVA
Rated AC Voltage400 V
DC SwitchYes
Operating Temperature Range-25 °C ~ +60 °C