EasyManua.ls Logo

Sungrow SG15RT - Page 134

Sungrow SG15RT
153 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
124
Parameter SG3.0RT SG4.0RT
Feed-in phases / connec-
tion phases
3 / 3
Efficiency
Max. efficiency 98.20 %
European efficiency 96.50 % 97.00 %
Protection & Function
Grid monitoring Yes
DC reverse connection
protection
Yes
AC short-circuit protection Yes
Leakage current
protection
Yes
DC switch Yes
PID recovery function Yes
Surge Protection DC Type II / AC Type II
Arc fault circuit interrupter
(AFCI)
optional
Protective Class I
Overvoltage Category
DC II/AC III
Active Anti-Islanding
Method
Frequency Shift
General Data
Dimensions (W x H x D) 370 mm x 480 mm x 195 mm
Mounting method Wall-mounting bracket
Weight 18 kg
Topology Transformerless
Degree of protection IP65
Operating ambient tem-
perature range
-25 to +60
Allowable relative humid-
ity range (non-
condensing)
0–100 %
Max. operating altitude 4000 m (> 2000 m derating)
Cooling method Natural cooling
Display LED
Communication WLAN / Ethernet / RS485 / DI / DO
DC connection type MC4 (Max. 6 mm
2
)
AC connection type Plug and play
10 Appendix User Manual