Model | SG110CX |
---|---|
Rated Output Power | 110 kW |
Max. Input Voltage | 1100 V |
Start Voltage | 200 V |
Max. Input Current per MPPT | 30 A |
Number of DC Inputs per MPPT | 2 |
THDi | < 3 % |
Euro Efficiency | 98.5 % |
Topology | Transformerless |
MPPT Voltage Range | 200 V - 1000 V |
Rated AC Voltage | 400 V |
AC Voltage Range | 310 V - 480 V |
Rated Grid Frequency | 50 Hz / 60 Hz |
DC Switch | Yes |
Operating Temperature Range | -25 °C ~ +60 °C (Derating above 45°C) |
Cooling Method | Forced air cooling |
Humidity Range | 0-100% (non-condensing) |
General precautions for installation, operation, and maintenance.
Safety guidelines for unpacking and inspecting the product.
Crucial safety measures to follow during product installation.
Critical safety measures for electrical connections.
Safety guidelines during product operation.
Safety protocols for product maintenance.
Overview of the inverter's role in a PV power system.
Essential safety precautions for installing the inverter.
Criteria for selecting an appropriate installation site.
Critical safety warnings for electrical connections.
Guidelines for connecting the inverter to the AC grid.
Procedures for connecting the DC input cables from PV strings.
Pre-checks before starting the inverter.
Step-by-step guide to start up the inverter.
Steps to safely disconnect the inverter from power sources.
Common fault codes and their corrective measures.
General maintenance procedures and notices.
Detailed specifications of the inverter.