3 Electrical Connection Quick User Manual
10
The requirements of PV cables are as follows.
Cross-section
Cable Diameter
Max. Withstand
Voltage
Max. Withstand
Current
4 mm
2
6 mm
2
6 mm9 mm
600 V
Equal to or greater
than short-circuit
current
Strip the insulation from the cables by 7 mm8 mm.
Tighten the cable gland with torque of 2.5 Nm3.0 Nm.
Positive crimp contact
Negative crimp contact
Crimp contact
Positive insulator
Cable gland
Negative insulator
Crimp contact
Cable gland
1
PV2
PV2
PV1
PV1
480.0
+
-
3
2
ON
OFF
4
+
-
PV
+
-
-
+
PV
+
PV
-
PV
* (-D series) Seal the unused PV terminals with the terminal caps.
The inverter will not function properly if any PV polarity is reversed.
If the PV connectors are not assembled into place, it may cause an arc
or overheat. The loss caused by this issue will void the warranty.