24
Item
Requirement
Source
Lifting rope 1
The lifting rope can be a sling or a nylon
rope.
The lift ropes 1 must be the same in length
(≥ 3,500mm).
The load that a single rope 1 can withstand,
both should be ≥4000kg.
When the wire rope is selected, the tensile
strength of the wire rope 1.Strength not less
than 1670MPa, wire diameter not less than
24mm.
Beyond the scope of
supply.
Lifting rope 2
The sling can choose flexible rope or nylon
belt.
The length of sling 2 must be the same, both
should be ≥4500mm.
The load that a single rope 2 can bear
should be ≥4000kg.
Beyond the scope of
supply.
Suspension
arm
Special tools In the scope of supply.
Wooden
blocks
-
In the scope of supply.
Further Operations
After hoisting and positioning the inverter, before putting the inverter into operation, be sure
to remove the wooden blocks on the top of the inverter to avoid affecting the air intake.
5 Mechanical Installation System Manual