EasyManuals Logo

Sungrow SH5K Replacement

Sungrow SH5K
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
!
Sungrow Australia Group Pty. Ltd. | 1800 SUNGROW (786 476)
service@sungrowpower.com.au | www.sungrowpower.com.au
SH5K_GD_LCD Replacement_201804 Page 1 of 2
LCD Replacement
Please follow the step-by-step instructions when you replace an SH5K LCD.
1. Shutdown Procedure:
a. Turn off the solar supply main switch (located next to the inverter or in
the switchboard).
b. Turn off the DC PV array isolator (located next to the inverter).
c. Turn off the battery circuit breaker and battery, if applicable.
d. Wait for the inverter LED and LCD to turn off.
2. Unlock and open the enclosure lid.
3. Unscrew four screws (the screw positions are shown in Figure 1).
Figure 1: Old LCD
4. See the LCD back side (Figure 3) and terminals on the SH5K (Figure 4: Figure
4).
5. Align the new SH5K LCD screw holes (Figure 3) with the SH5K screw
receptacles (Figure 4) and the 20 LCD pins (Figure 3) with the 20 pins LCD port
on the SH5K (Figure 4), and tighten the screws (Figure 2).
Figure 2: New LCD

Other manuals for Sungrow SH5K

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SH5K and is the answer not in the manual?

Sungrow SH5K Specifications

General IconGeneral
BrandSungrow
ModelSH5K
CategoryInverter
LanguageEnglish

Related product manuals