51
When performing AC wiring (LOAD or GRID), check carefully if the cable wires
match the ports properly. Incorrect wiring will damage the inverter.
step 7 Ensure that the wires are securely in place by slightly pulling them. Tighten the swivel nut to
the housing.
step 8 Insert the AC connector into the GRID and LOAD terminal on the inverter until there is an
audible sound.
High voltage may be present in inverter!
Ensure all cables are voltage-free before electrical connection.
Do not connect the AC circuit breaker until all inverter electrical connections are
completed.
step 9 Lock the AC connector using a slotted screwdriver.
User Manual 6 Electrical Connection