SWIMMING POOL HEAT PUMP UNIT
Installation & Instruction Manual
X 19 | X 24

Questions and Answers

  • A
    Ashley AllenAug 15, 2025
    What to do if my Sunlover Oasis X shows a flow switch failure?
    • P
      Patrick McneilAug 15, 2025
      If the Sunlover Heat Pump displays a flow switch failure, it could be due to insufficient water in the water system. Check the water flow volume and verify the water pump's functionality.
  • A
    Andrew PriceAug 18, 2025
    Why does my Sunlover Oasis X Heat Pump show high pressure protect?
    • J
      Jacqueline JonesAug 18, 2025
      The 'High pressure protect' error on your Sunlover Heat Pump indicates that the exhaust pressure is too high, triggering the high-pressure switch. You should check the high-pressure switch and the cooling return circuit.
  • J
    Jacob ZimmermanAug 21, 2025
    Why does my Sunlover Heat Pump show low pressure protect?
    • R
      Rickey PrinceAug 21, 2025
      The 'Low pressure protect' error on your Sunlover Heat Pump means the suction pressure is low, activating the low-pressure switch. Check the low-pressure switch and the cooling return circuit.
  • S
    Seth CampbellAug 25, 2025
    What to do if the Sunlover Oasis X displays a communication failure?
    • A
      Ashley WatsonAug 25, 2025
      If your Sunlover Heat Pump is showing a communication failure, it means there's a communication issue between the remote wire controller and the main board. You should check the wire connection between these two components.
  • G
    Glenn LucasAug 27, 2025
    What to do if the temperature difference is too much between water-inlet and outlet in Sunlover Oasis X?
    • M
      Maria DavisAug 27, 2025
      If there's a significant temperature difference between the water inlet and outlet in your Sunlover Heat Pump, it might be caused by insufficient water flow or a small water system pressure difference. Check the flow volume and ensure the water system isn't jammed.
  • T
    Tony YoungAug 30, 2025
    What causes antifreezing under cooling mode in a Sunlover Oasis X and how to fix it?
    • S
      stephen33Aug 30, 2025
      Antifreezing during cooling mode in your Sunlover Heat Pump can occur if the water flow volume is not enough. You should check the flow volume and ensure the water system is not blocked.
  • G
    gabriel24Sep 3, 2025
    What to do if my Sunlover Oasis X has a water inlet temp sensor failure?
    • D
      David WoodSep 3, 2025
      If your Sunlover Heat Pump indicates a water inlet temperature sensor failure, it's likely that the sensor is either open or short-circuited. You should check or replace the water inlet temperature sensor.
  • E
    Elizabeth CarrSep 5, 2025
    What to do if my Sunlover Oasis X Heat Pump has a water outlet temp sensor failure?
    • T
      tyler71Sep 5, 2025
      If your Sunlover Heat Pump reports a water outlet temperature sensor failure, the sensor is likely open or short-circuited. You should check or replace the water outlet temperature sensor.
  • O
    osotoSep 8, 2025
    How to fix ambient temp sensor failure in Sunlover Oasis X Heat Pump?
    • T
      timothy04Sep 8, 2025
      If your Sunlover Heat Pump shows an ambient temperature sensor failure, it means the sensor is either open or short circuit. To resolve this, check or change the ambient temperature sensor.
  • J
    Jason MillerSep 12, 2025
    What does evaporator temp sensor failure mean on my Sunlover Oasis X?
    • K
      Kelly OsbornSep 12, 2025
      An evaporator temperature sensor failure on your Sunlover Heat Pump indicates that the sensor is either open or short circuit. To fix this, check or replace the evaporator temperature sensor.

Summary

Specification

2.1 Performance data of Swimming Pool Heat Pump Unit

Technical performance metrics for the heat pump unit under various conditions.

Installation and Connection

3.4 Swimming Pool Heat Pumps Plumbing

Instructions for connecting the heat pump to the pool's water circulation system using PVC pipes.

Usage and Operation

4.2 The controller usage

Detailed instructions on operating the heat pump controller, including modes and settings.

4.2.C - Temperature setting

Guide on how to adjust and set the desired water temperature for the heat pump.

4.2.E - Timer setting

Instructions for programming the automatic on/off timer for the heat pump unit.

Maintenance and Inspection

5.2 Trouble Shooting Guide

A comprehensive guide to diagnose and resolve common malfunctions using display codes.

Appendix

6.1 Caution & Warning

Important safety precautions, warnings, and compliance information for the unit's use.