Sunpak® Infrared Heaters
14
TroubleShootingRemoteControls
ErrorCode: Reason Solution
Modulehasfour“beeps”everyone
second
Warnsuserthatthepilot
flamesensordetectsapilot
flamealreadypresentwhen
ignitionsequenceis
initiated.Thisfaultwill also
occurifpilotflamesensoron
maincontrolmoduleis
shortedtoground
Adjustthesensorelectrodeto3/16”
forthepilot
hoodand3/8”fromthe
sparkelectrode.Makesurethe
electrodeiswithintheflamezone.
Fourbeepseverytwoseconds Warnusersthemodule’s
internaltemperaturehas
exceeded170⁰F.(77⁰)
Module’sinternaltemperaturesmust
cooltobelow160⁰F(71⁰C)andthen
pressONbutton
Onebeepeveryfourseconds FlameSafetyCircuithas
lockedout
PressOFFbuttontoresetthenONto
restartheater
EachSunpakTSRcomeswithwirelesscontrolspre‐programmedforindividualheaters.Ifyouhavea
problemwiththeremotes,pleasereviewthefollowing:
1. Makesurethereispowertotheunitthrough7.5VDCoutputfromtheplug‐inpoweradapter.
2. Makesureyouhavethecorrectcontrol
fortheheater.Eachcontrolismarkedwitha number
correspondingtothelabellocatedonthelouverendoftheheater.
3. Makesureyoupressthe<ON>buttonfor1fullsecondtoallowthecontroltorespond.
4. Makesuretheredindicatorlights upwhilepressing
the<ON>button.Replacebatteriesif
necessary.
5. Eachheatercomeswithtwowirelesscontroldevices.Trytheothercontroldevice.
6. Press<OFF>toRESETsystemandthenpress<ON>.Afterafewsecondsyousho uldhearan
audibleclickfromthecontrolinsidetheheaterandseeaspark
atthepilotbehindthefacegrille.
Iftheaboveprocedurefailstogetresultsitmaybenecessarytore‐programtheheatercontrol.The
diagramintheinstructionsshowsthelocationoftheprogrammingbuttoninsidetheheater.Thisbutton
maybeaccessedthroughtheportonthe
frontpaneloftheheater. Asmall rodsuchasabentheavily
dutypaperor1/8inchpinwillbenecessarytoreachthebutton.
Theheatercontrolcommunicatesusingaseriesofbeeps.Inanoisyenvironmentthesebeepsmaybe
hardtohear.Thoughthese beepsarehelpful
theyarenotnecessarytoforprogrammingtheheater.
1. Selectthewirelessdeviceyouwanttheusewiththeheater.