MAXEONSOLARTECHNOLOGIES,LTD.
SafetyandInstallationInstructions‐Document00115497Rev.W
©December2021MaxeonSolarTechnologies,Ltd.Allrightsreserved.Specificationsincludedinthismanualaresubjecttochangewithoutnotice.
Platform Modulemountingandgroundholedetail FrameProfile
FORPSERIESCOMMERCIALGEN4.1FRAMEMODULES
Commercial
Modules
SIDEFRAMEPROFILE
ENDFRAMEPROFILE
FORPSERIESCOMMERCIALGEN4.2FRAMEMODULES
Commercial
Modules
SIDEFRAMEPROFILE
ENDFRAMEPROFILE
FOR104cGEN4.2FRAMEMODULES
Commercial
Modules
SIDEFRAMEPROFILE
ENDFRAMEPROFILE
998 mm
46 mm
MODEL: SPR-P19-410-COM
Rated Power (Pmax)
1
(+5/
0
%) 410
W
Voltage (Vmp) 43.9
V
Current (Imp) 9.35
A
Open-Circuit Voltage (Voc) 53.1
V
Short-Circuit Current (Isc) 9.94
A
Maximum SeriesFuse 15
A
1
Standard Test Conditions: 1000 W/m
2
, AM 1.5, 25° C
Suitable for ungrounded, positive, or negative grounded DC systems
Field Wiring: Cu wiring only, min. 12 AWG/4 mm
2
, insulated for 90° C min.
WARNING
SEVERE ELECTRICAL HAZARD
• Solar module has full voltage even in very low light.
• Installation should only be done by a qualified technician.
527040
www.sunpower.com
Patented as shown at www.sunpower.com/patents
Safety Class II
Fire Rating: Class C
Max. System Voltage:1500 V DC
954 mm
961 mm
2067 mm
30
0 mm
400 mm
539 mm
1058 mm
1200 mm
1423 mm
1606 mm
4X Ø 4.2mm
Ground Holes
20X Ø 6.8mm
Mounting Holes
4X 5.0mm (W) x 15.0mm (L)
SLOT
46mm
32mm
46mm
24 mm
998 mm
40 mm
MODEL: SPR-P19-410-COM
Rated Power (Pmax)
1
(+5/
0
%) 410
W
Voltage (Vmp) 43.9
Current (Imp) 9.35
Open-Circuit Voltage (Voc) 53.1
V
Short-Circuit Current (Isc) 9.94
Maximum SeriesFuse 15
A
1
Standard Test Conditions: 1000 W/m
2
, AM 1.5, 25° C
Suitable for ungrounded, positive, or negative grounded DC systems
Field Wiring: Cu wiring only, min. 12 AWG/4 mm
2
, insulated for 90° C min.
WARNING
SEVERE ELECTRICAL HAZARD
• Solar module has full voltage even in very low light.
• Installation should only be done by a qualified technician.
527040
www.sunpower.com
Patented as shown at www.sunpower.com/patents
Safety Class II
Fire Rating: Class C
Max. System Voltage:1500 V DC
954 mm
961 mm
2067 mm
400 mm
539 mm
1058 mm
1200 mm
1423 mm
1606 mm
4X Ø 4.2mm
Ground Holes
18X Ø 6.8mm
Mounting Holes
4X 5.0mm (W) x 15.0mm (L)
SLOT
32mm
40 mm
24 mm
40 mm
4x Ø 4.2 mm
Ground Holes
8x Ø 6.8 mm
Mounting Holes
1690 mm
1500 mm
1300 mm
1100 mm
1046 mm
1002 mm
32mm
40 mm
24 mm
40 mm
MeasurementTolerancesare+/3mmfortheLengthandWidthoftheModule.