MAXEON SOLAR TECHNOLOGIES, LTD.
Safety and Installation Instructions - Document 001-15497 Rev.AA
©June 2023 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Mounng
Configuraon
Descripon
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
50 - 150
Long Side Mounng,
Point Supported
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Point Supported
(End Mount)
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
150 - 272
50 - 150
150 - 272
272 - 453
453 - 710
50 - 150
150 - 272
272 - 453
453 - 710
0 - 350
0 - 350
+2700/-2700
+2700/-2700
+2700/-2700
+1800/-1800
+1800/-1800
+1800/-1800
+3600/-2400
+5400/-4200
+3600/-3600
+2700/-2700
+3600/-2400
+5400/-4200
+3600/-3600
+2700/-2700
+3600/-2400
+5400/-4200
+3600/-3600
+2700/-2700
+2400/-1600
+3600/-2800
+2400/-2400
+1800/-1800
+2400/-1600
+3600/-2800
+2400/-2400
+1800/-1800
+2400/-1600
+3600/-2800
+2400/-2400
+1800/-1800
TOP CLAMPS
Maxeon 3 112 cells AC Ready Solar Panel
(SPR-MAX3-XXX-R, SPR-MAX3-XXX-BLK-R, SPR-MAX3-XXX-COM-R)
GEN 5.2 FRAME PROFILE
SIDE FRAME PROFILE
END FRAME PROFILE
A - Ground Holes (4X Ø4.2mm)
B - Mounng Holes (8X Ø6.8mm)
1046 mm
1002 mm
1100 mm
1300 mm
1656 mm
1812 mm
0
B
272
453
150
710
0
272
453
150
710
0
350
0
A
50
50
350
Mounng
Configuraon
Descripon
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
1300mm Holes
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Long Side Mounng,
Point Supported
+5400/-5400
+5400/-5400
+5400/-5400
+3600/-3600
+3600/-3600
+3600/-3600
1100mm Holes
BOLTS
1300mm Holes
1100mm Holes
+5400/-5400
+3600/-3600
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
4 Rails must not be under the juncon box.
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
5
C
overed
un
der
IE
C 6173
0
Cert T
es
t
f
or
104
cel
l
1 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design load values should be considered as allowable design load.
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
pares, unless there is a formal authorizaon by Maxeon.
Short Side Mounng,
Rails Perpendicular to
Mounng Frame
(End Mount)
0 - 350
272 - 453
453 - 710
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Test Load
Downward/Upward
(Pa)
Test Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
32 mm
40 mm
40 mm
24 mm
6 Boom flange mounng.
7 Rails indicates posioning of the clamp and not the rails.

Related product manuals