MAXEON SOLAR TECHNOLOGIES, LTD.
Safety and Installation Instructions - Document 001-15497 Rev.AA
©June 2023 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
50 - 150
Long Side Mounng,
Point Supported
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Point Supported
(End Mount)
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
150 - 272
272 - 453
453 - 710
50 - 150
150 - 272
272 - 453
453 - 710
50 - 150
150 - 272
272 - 453
453 - 710
0 - 350
0 - 350
0 - 350
+2700/-2700
+2700/-2700
+2700/-2700
+1800/-1800
+1800/-1800
+1800/-1800
+3600/-2400
+5400/-4200
+3600/-3600
+2700/-2700
+3600/-2400
+5400/-4200
+3600/-3600
+2700/-2700
+3600/-2400
+5400/-4200
+3600/-3600
+2700/-2700
+2400/-1600
+3600/-2800
+2400/-2400
+1800/-1800
+2400/-1600
+3600/-2800
+2400/-2400
+1800/-1800
+2400/-1600
+3600/-2800
+2400/-2400
+1800/-1800
TOP CLAMPS
SunPower Maxeon 3 112 cells Residenal Solar Panel
(SPR-MAX3-XXX, SPR-MAX3-XXX-BLK)
1046 mm
1002 mm
1100 mm
1300 mm
1500 mm
1812 mm
0
B
272
453
150
710
0
272
453
150
710
0
350
0
350
A
GEN 4.2 FRAME PROFILE
SIDE FRAME PROFILE
END FRAME PROFILE
A - Ground Holes (4X Ø4.2mm)
B - Mounng Holes (8X Ø6.8mm)
50
50
32 mm
40 mm
24 mm
40 mm
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
1300mm Holes
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Long Side Mounng,
Point Supported
+5400/-5400
+5400/-5400
+5400/-5400
+3600/-3600
+3600/-3600
+3600/-3600
1100mm Holes
BOLTS
1300mm Holes
1100mm Holes
+5400/-5400
+3600/-3600
Test Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
Test Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
4 Rails must not be under the juncon box.
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
5
C
o
ve
r
e
d
u
n
d
e
r
I
E
C
6
1
7
3
0
C
e
r
t
Te
s
t
f
o
r
1
0
4
ce
ll
Short Side Mounng,
Rails Perpendicular to
Mounng Frame
(End Mount)
Mounng
Configuraon
Descripon
Mounng
Configuraon
Descripon
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
1 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design load values should be considered as allowable design load.
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
pares, unless there is a formal authorizaon by Maxeon.
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
6 Boom flange mounng.
7 Range indicates posioning of the clamp and not the rails.