MAXEON SOLAR TECHNOLOGIES, LTD.
Safety and Installation Instructions - Document 001-15497 Rev.AA
©June 2023 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
0 - 150
Long Side Mounng,
Point Supported
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Point Supported
(End Mount)
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
150 - 311
311 - 554
554 - 885
0 - 150
150 - 311
311 - 554
554 - 885
0 - 150
150 - 311
311 - 554
554 - 885
0 - 350
0 - 350
0 - 350
+2400/-2400
+2000/-2000
+2400/-2400
+1600/-1600
+1333/-1333
+1600/-1600
+3600/-3600
+5400/-3600
+3600/-3600
+2000/-2000
+3600/-3600
+5400/-3600
+3600/-3600
+2000/-2000
+5400/-3600
+5400/-3600
+5400/-3600
+2000/-2000
+2400/-2400
+3600/-2400
+2400/-2400
+1333/-1333
+2400/-2400
+3600/-2400
+2400/-2400
+1333/-1333
+3600/-2400
+3600/-2400
+3600/-2400
+1333/-1333
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
1423mm Holes
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Long Side Mounng,
Point Supported
1200mm Holes
539mm Holes
+5400/-3600
+3600/-3600
+3600/-3600
+3600/-3600
+5400/-3600
+5400/-3600
+3600/-2400
+2400/-2400
+2400/-2400
+2400/-2400
+3600/-2400
+3600/-2400
400mm Holes
300mm Holes
400mm Holes
TOP CLAMPS
BOLTS
SunPower Maxeon 3 128 cells Solar Panel
(SPR-Xyy-XXX-COM)
1046 mm
1002 mm
300 mm
1058 mm
1200 mm
1423 mm
2047 mm
0
C
311
554
150
885
0
311
554
150
885
0
350
0
350
E
D
A
B
GEN 4.0 FRAME PROFILE
SIDE FRAME PROFILE
END FRAME PROFILE
32 mm
46.08 mm
3.18 mm
10.30 mm
18.50 mm
2.20 mm
22 mm
46.08 mm
10.50 mm
1.27 mm
400 mm
539 mm
398 mm
1423mm Holes
1200mm Holes
539mm Holes
300mm Holes
A - Drainage Holes (4X Ø4.8mm)
B - Stacking Pins (4X Ø6.10mm)
C - Mounng Holes (24X Ø6.8mm)
D - Slots (4X 5.0mm(W) x 15.0mm(L))
E - Ground Holes (4X Ø4.2mm)
+3600/-3600
+2400/-2400
+2400/-2400
+3600/-3600
+3600/-3600
+2400/-2400
+5400/-3600
+3600/-2400
1 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design load values should be considered as allowable design load.
4 Rails must not be under the juncon box.
Test Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
5
T
he
r
e
is a
20
m
m
z
one
a
t 38
8
-4
0
8
m
m
f
r
om
the corne
r
whe
re m
oun
n
g
is not a
llow
e
d due
to the
s
ta
cking
pi
n
.
Test Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Short Side Mounng,
Rails Perpendicular to
Mounng Frame
(End Mount)
Mounng
Configuraon
Descripon
Mounng
Configuraon
Descripon
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
pares, unless there is a formal authorizaon by Maxeon.
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
6 Boom flange mounng.
7 Range indicates posioning of the clamp and not the rails.

Related product manuals