MAXEON SOLAR TECHNOLOGIES, LTD.
Safety and Installation Instructions - Document 001-15497 Rev.AA
©June 2023 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
50 - 150
Long Side Mounng,
Point Supported
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Point Supported
(End Mount)
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
150 - 296
296 - 536
536 - 825
50 - 150
150 - 296
296 - 536
536 - 825
50 - 150
150 - 296
296 - 536
536 - 825
0 - 350
0 - 350
0 - 350
+2400/-1600
+1800/-1600
+1800/-1600
+1200/-1067
+1200/-1067
+1600/-1067
+2400/-2400
+5400/-2400
+2400/-2400
+1800/-1800
+2400/-2400
+5400/-2400
+2400/-2400
+1800/-1800
+2400/-2400
+5400/-3600
+2400/-2400
+1800/-1800
+1600/-1600
+3600/-1600
+1600/-1600
+1200/-1200
+1600/-1600
+3600/-1600
+1600/-1600
+1200/-1200
+1600/-1600
+3600/-2400
+1600/-1600
+1200/-1200
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
1423mm Holes
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
Long Side Mounng,
Point Supported
1200mm Holes
400mm Holes
+2400/-2400
+2400/-4500
+2400/-4500
+2400/-2400
+5400/-4500
+5400/-4500
+1600/-1600
+1600/-3000
+1600/-3000
+1600/-1600
+3600/-3000
+3600/-3000
1423mm Holes
1200mm Holes
400mm Holes
TOP CLAMPS
BOLTS
GEN 5.6 FRAME PROFILE
A - MLSD Holes
B - Mounng Holes (16X Ø6.8mm)
C - Ground Holes (4X Ø4.2mm)
SunPower Maxeon 6 72 cells Commercial Solar Panel
(SPR-MAX6-XXX-COM)
1039 mm
995 mm
400 mm
1200 mm
1423 mm
1653 mm
2047 mm
0
32 mm
35 mm
32 mm
35 mm
A
B
C
SIDE FRAME PROFILE
END FRAME PROFILE
50
296
536
150
825
0
50
296
536
150
825
0
350
0
350
Test Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
Test Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
4 Rails must not be under the juncon box.
Mounng
Configuraon
Descripon
Mounng
Configuraon
Descripon
Short Side Mounng,
Rails Perpendicular to
Mounng Frame
(End Mount)
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
1 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design load values should be considered as allowable design load.
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
pares, unless there is a formal authorizaon by Maxeon.
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
5 Boom Flange Mounng
6 Range indicates posioning of the clamps and not the rails.