MAXEON SOLAR TECHNOLOGIES, LTD.
Safety and Installation Instructions - Document 001-15497 Rev.AA
©June 2023 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
Mounng
Configuraon
Descripon
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
546 - 646
Design Load
Long Side Mounng,
Rails Perpedincular to
Mounng Frame
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Point Supported
(End Mount)
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
646 - 1042
50 - 546
0 - 323
0 - 223
Test Load
+1400/-1400
+5400/-1200
+2400/-2000
+5400/-2400
+933/-933
+3600/-800
+1600/-1333
+3600/-1600
Mounng
Configuraon
Descripon
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
1400mm Holes
Design Load
Long Side Mounng,
Rails Perpedincular to
Mounng Frame
1100mm Holes
400mm Holes
Test Load
+1800/-1800
+2400/-2000
+5400/-2400
+5400/-2400
+1200/-1200
+1600/-1333
+3600/-1600
+3600/-1600
400mm Holes
TOP CLAMPS
BOLTS
GEN 4.3 FRAME PROFILE
A - SLOT Holes (8X 14mm (L) x 9mm (W), R3.5mm)
B - Mounng Holes (4X 10mm (L) x 7mm (W), R6.8mm)
C - Ground Holes (4X Ø 4.2mm)
SunPower Performance 5 & 6 Bifacial Solar Panel
(SPR-P5-XXX-UPP, SPR-P6-XXX-COM-M-BF)
1092 mm
1043 mm
400 mm
1100 mm
1400 mm
2384 mm
0
646
0
A
B
C
SIDE FRAME PROFILE
END FRAME PROFILE
Short Side Mounng,
Point Supported
with Rail
(End Mount)
35 mm
16 mm
35mm
35 mm
0 - 323
1088.77
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
546
1232.77
1042
1042
646
546
323
0
323
Center Mounng
(1x Portrait Tracker)
7 Minimum of 24mm in diameter washer size is required.
50 - 546
+2400/-1200
+1600/-800
+3600/-2400
+1400/-1400
+2400/-1600
+933/-933
Downward/Upward
(Pa)
Downward/Upward
(Pa)
Downward/Upward
(Pa)
Downward/Upward
(Pa)
Long Side Mounng,
Point Supported
50 - 150
+1800/-1800
+1200/-1200
546 - 646
+3000/-2400
+2000/-1600
3 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
pares, unless there is a formal authorizaon by Maxeon.
0
Measurement Tolerances are +/-3 mm for the Length and Width of the Module.
5 Boom flange mounng.
50
50
6 Range indicates posioning of the clamp and not the rails.
4 IEC validated.
1 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design values should be considered as allowable design load.
546 - 646
+5400/-2400
+3600/-1600
223 - 323
+2400/-1200
+1600/-800