MAXEON SOLAR TECHNOLOGIES, LTD.
Safety and Installation Instructions - Document 001-15497 Rev.AA
©June 2023 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this manual are subject to change without notice.
2 Test loads are for informaon purposes only, design loads should be considered for the project design.
 Design Load considers 1.5 Factor of Safety, Test load = Design load x 1.5. Product Warranty covers only design
load values. The design loads listed in this table supersede all other loads that may be defined by other
pares, unless there is a formal authorizaon by Maxeon.
Mounng
Configuraon
Descripon
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
50 - 496
Long Side Mounng,
Rails Perpedincular to
Mounng Frame
Long Side Mounng,
Rails Parallel to
Mounng Frame
Short Side Mounng,
Rails Parallel to
Mounng Frame
(End Mount)
596 - 942
+3000/-2400
+2000/-1600
+2400/-1600
+1800/-1600
+2000/-1600
+1600/-1066
+1600/-1066
+1200/-1066
TOP CLAMPS
GEN 4.3 FRAME PROFILE
A - Ground Holes (4X Ø 4.2mm)
B - Mounng Holes (8X 9mm (W) x 14mm (L), R4.5mm)
SunPower Performance 6 COM-S BIFACIAL Solar Panel
(SPR-P6-XXX-COM-S-BF)
1092 mm
2185 mm
0
B
SIDE FRAME PROFILE
END FRAME PROFILE
Short Side Mounng,
Point Supported
(End Mount)
0
323
1400 mm
596
496
0
0
496 - 596
+5400/-2400
+3600/-1600
Long Side Mounng,
Point Supported
0 - 100
+1200/-1000
+800/-666
50
Test Load
Downward/Upward
(Pa)
Design Load
Downward/Upward
(Pa)
942
35 mm
30 mm
35 mm
16 mm
A
1051 mm
Mounng
Configuraon
Mounng Configuraon Diagram
Front View
Back View
Mounng Zone
Locaons
(distance from corner
in mm)
1100mm Holes
Design Load
Long Side Mounng,
Rails Perpendincular
to Mounng Frame
1400mm Holes
Test Load
+5400/-2400
+5400/-2400
+3600/-1600
+3600/-1600
BOLTS
Downward/Upward
(Pa)
Downward/Upward
(Pa)
Descripon
3 In the cases where hybrid mounng is necessary (combinaon of long and short side mounng), the lowest
design load values should be considered as allowable design load.
223 - 323
+2400/-1400
+1600/-933
596 - 942
496 - 596
323
50 - 496
+1800/-1600
+1200/-1066
50 - 496
+2800/-1800
+1867/-1200
496 - 596
+2800/-1800
+1867/-1200
596 - 942
+2800/-1800
+1867/-1200
4 Boom flange mounng
596
496
50
942
Measurement Tolerances are +/-3mm for the Length and Width of the module.
1100 mm
100 - 323
+1600/-1600
+1066/-1066
5 Range indicates posioning of the clamp and not the rails.