MODULE TYPE/S
SP170-36P
SP165-36P
SP160-36P
Voc (with tolerance) [V]........ :
23.44±3%
22.92±3%
22.56±3%
I
sc
(with tolerance) [A]
..........
:
9.27±3%
9.17±3%
9.02±3%
V
Pmax
[V]
................................
:
19.84
19.08
18.81
IPmax [A]..................................:
8.73
8.65
8.51
P
max
(with tolerance) [W]
.....
:
170±3%
165±3%
160±3%
Maximum System Voltage [V]:
1500
1500
1500
Maximumover-Current Protection
Rating [A]:
20
20
20
Calculated NMOT:
42.8
4UNPACKING SAFETY 拆包安全
1
At time of receipt, verify that the product delivered is in fact the product ordered the product name,
subname, and serial number of each laminate are clearly marked on the outside of each packing box.
收货时,认发货产品实是订的产品,在每包装盒外面楚地标每个托盘的产名称、子
和序列号。
2For unpacking outdoors, it is prohibited to operate in rainy conditions. Because the carton will become
soft and damaged after it gets wet in the rain. The stacked PV modules (hereinafter referred to as "modules") may
tip over, which may cause damage or injury to personnel.
在户外拆包时,禁止在雨中作业。因为外包装纸箱会受潮而变软或者损坏,包装箱里的组件有可能会发生倾斜
倾倒将导致组件损坏以及人员伤害。
3For a windy site, it is necessary to pay special attention to safety. Especially, it is not recommended to
transport or unpacking the modules in high wind conditions. The unpacked modules must be tied down to avoid