文件编号 Document No.SP/WI-JS-010
- 28 -
installation, dismantling, maintenance and any other related process of the Product.
安装意事了将接雷击风险降到最低在设计系时应避免形成路。为避免人因素造成线
与连接器、线缆与线盒连接不良损坏,影响产品电安全或使用寿命,议产品在安装拆卸、维护及何其
它相关过程中,施加在线缆和连接器、线缆和接线盒之间的作用力不得大60N
Pay attention to the direction of the wire when installing the modules. It should be connected along the wire
direction to avoid bending the wire.
注意组件安装时的导线方向,应顺着导线方向连接,避免导线折弯。
2Electrical Connection
The Direct Current (DC) generated by the PV system can be converted to Alternating Current (AC) and
connected to the public power grid. Different regions may have different policies, laws and regulations to stipulate
the installation and grid-connection requirements of PV systems. Therefore, during the design, installation and
grid-connection of PV system, please comply with the local policies, laws and regulations.
光伏系统生的直电可转换成流电,并公共网相连不同区可能不同的政和法法规来
光伏系统的安装要求和并网要求,因此在光伏系统的设计、安装和并网过程中,请遵守当地的政策和法律法规要求。
PV modules can obtain different current and voltage outputs through series connection and parallel
connection. Read this installation manual carefully before electrical connection and installation. Please design and
connect according to the current and voltage required by customers. Before connection, please ensure that the
connection part is free from corrosion, and keep it clean and dry.
光伏组件过串联并联连接方可以获得同的流和电输出在进行气连接和装前请仔细
本安装手册,并依据客户所要求的电流和电压进行设计和连线。连接前请确保连接部分无腐蚀,保持清洁和干燥。
Different types of modules cannot be connected in series. Modules connected in series should ensure the
consistency of their current. The voltage of the module string should not exceed the allowable system voltage
value, which can be found on the nameplate or datasheet of the module.
不同类型组件产不能联在一,串联在起的件产品保证电流的致性,组串的压不能
所允许的组件系统电压值,该电压值可以在组件的铭牌或者规格书里找到
Sunpro Power modules are provided with stranded copper cables with a cross sectional area of 4mm ²
which are rated for 1500V dc, 90°C and are UV resistant. All other cables used to connect the DC system should
have a similar (or better) specification. Sunpro Power recommend that all cables are run in appropriate conduits
and sited away from areas prone to water collection.
Sunpro Power 4mm² 的铜线额定 1500V dc90°C紫外线 用于
流系所有其他应具似(或更规格 Sunpro Power 议将有电铺设的导中,
远离容易积水的区域。
The maximum number of modules in series depends on the system design, the type of converter used and
the environmental conditions. In general, the maximum number (N) of PV modules in series can be calculated by
dividing the maximum system voltage by the open circuit voltage of the relevant Solar PV modules. When
designing the Solar PV system, it is necessary to take into account the characteristic that the voltage of the
Solar PV module changes with the temperature. Considering the voltage increase caused by temperature drop in
extreme environment in winter, the maximum series connection number of Solar PV modules can be calculated
by the following formula.
串联组件最大数取决系统设、所用变器的型和环条件通常情下,最大串联阳能光
件数N可以统最除以阳能组件压的算而,但计太
系统时,一定要考到太阳能光伏件的电压随着温度化而变化的特性。虑到冬季里极环境下温度下造成

Related product manuals