22) Use of Chip Discharge Guide and Auxiliary Needle Plate (KM-506/530 Series)
(1) When Cutting and Sewing Simultaneously
When cutting and sewing are done at the same time, attach the chip discharge guide, which is provided in the accessory
box, to the auxiliary needle plate with fixing screws. (See Fig. 50)
(2) When Sewing Only
When sewing is done alone without cutting, remove the chip discharge guide(upper) and the insert the auxiliary needle
plate cover, which is provided in the accessory box, into the chip discharge groove in the auxiliary needle plate. (See
Fig. 51)
[Fig. 50] [Fig. 51]
(1) Disassembly
A. Loosen the needle fixing screw and remove the needle.
B. Loosen the presser foot fixing screw and separate the presser foot.
C. Loosen the needle plate fixing screw and separate the needle plate.
D. Loosen the feed dog fixing screw and separate the feed dog.
E. Loosen the auxiliary needle plate fixing screw and separate the auxiliary needle plate.
F. Loosen the chip discharge guide(lower) fixing screw from the separated auxiliary needle plate and separate the
chip discharge guide.
G. Loosen the knife fixing screw and separate the knife.
23) Change of Cutting Width
[Fig. 52]
Keystone Sewing Machine Company, Inc.