Machine Adjustment
Caution
Always turn off the power when mounting a needle.
If the operator mistakenly steps on the pedal while the power is on, the machine will start
automatically and can result in physical injuries.
When using clutch motor, be aware that the motor will continue to rotate for a while even after the
power is switched off due to inertia. Start to work on the sewing machine only after the motor has
come to a complete stop.
Caution
Turn off the power when adjusting the lower thread tension.
If the operator mistakenly steps down on the pedal while switched on, the machine will start
automatically and can cause physical injuries.
When using the clutch motor, be aware that the motor will continue to rotate for a while after the
power is switched off. Start to work only after the motor has come to a complete stop.
1) Inserting needle
As in Figure 17, move the needle upper end so that it
directly touches the upper side of the stopper hole when
the groove of the needle is facing inward. Then, use the
fixing screw to fix the position of the needle.
2) Removing bobbin and bobbin case
Place the needle in the highest position, and then like in Figure 18, open the hook covers on the left and right, lift the
bobbin holder to remove the bobbin case and the bobbin .
[Figure 17]
[Figure 18]
[ KM-967 Series ]
[ KM-957 Series ]