Function No. : 009 Function Name : Main shaft speed acceleration
It sets the sewing speed acceleration when sewing starts.
Default value: SLOW_START3 (In case of SPS/A/B-1507, SLOW_START1)
009. Slow Start
[ Caution ] In the case where the sewing speed set by user is slower than the stitching
speed, the user-defined sewing speed will prevail.
The set value may vary depending on models. For functional enhancement, it can be
changed.
Setting
Value
Features
1) SLOW_START0
2) SLOW_START1
3) SLOW_START2
4) SLOW_START3
5) SLOW_START4
6) SLOW_START5
7) USER_START
Needle speed
Series
1
st
Needle
Speed
2
nd
Needle
Speed
3
rd
Needle
Speed
4
th
Needle
Speed
5
th
Needle
Speed
6
th
Needle
Speed
7
th
Needle
Speed
8
th
Needle
Speed
Remarks
A/B
200
300
400
500
500
600
200
200
200
200
200
200
400
500
500
600
500
600
200
200
200
200
400
400
600
700
800
900
500
600
400
400
200
400
400
400
800
900
1000
1100
800
800
800
800
400
400
600
600
1000
1200
1200
1300
1000
1200
1200
1000
600
600
800
800
1600
1200
800
800
1200
1200
1800
1400
1000
1200
1600
1600
2000
1600
1200
1400
1800
2000
During
embroidery
work
User
define
C A/B C A/B C A/B C A/B C A/B C A/B C A/B C
1800
1600
1400
1200
1000
800
600
400
200
0
2200
2000
1800
1600
1400
1200
1000
800
600
400
200
0
0
0234567891011
Needle 1
SLOW_START5
SLOW_START5
SLOW_START2
SLOW_START3
SLOW_START0
SLOW_START4
SLOW_START1
User define
SLOW_START1
SLOW_START0
SLOW_START2
SLOW_START3
SLOW_START4
User define
Needle 2 Needle 3 Needle 4 Needle 5 Needle 6 Needle 7 Needle 8 Needle 9 Needle 10
[ Features of sewing
speed acceleration ]
[SPS/A/B-Series]
[SPS/C-Series]

Related product manuals