EasyManua.ls Logo

SunStar SPS/A-Pattern Series - Page 158

SunStar SPS/A-Pattern Series
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
158
Function No. : 097
Function Name: Design Call Sensor Time Setting
[Possible when SPS/C-Series I/O Board is used]
This function is to set the time of the design auto call sensor (SEN_0~SEN_3).
󱄹 Sensor connection method may differ by model types.
10 [Unit 100ms] (default)
[Contents] The sensing time between the first sensor and the next sensor can be set. The basic
unit is 100ms. When "10" is set at the parameter, it means 1000ms or 1 second. This
function is aimed to set the time difference between the sensing acts of different
sensors to ensure accurate sensing.
097. AutoCall TM
10
Setting
Value
Function No. : 096
Function Name: External Control Signal Use Setting
[Possible when SPS/C-Series I/O Board is used]
This function is to use the external input signals to use Sewing Start, Emergency Switch, Clamp and Enter
Key.
The function is disabled (default).
[Contents] When the function is disabled, it is same as the previous usage.
The function is enabled.
[Contents] When the function is enabled, it is possible to use the external input signals to use
Sewing Start, Emergency Switch, Clamp Up/Down, and Enter key.
096. Attatch Set
1) DISABLE
2) ENABLE
Setting
Value
Function No. : 098 Function Name: Upper thread holder setting (C-Series AIR BAG model)
It sets whether to make the upper thread holder hold the needle thread after trimming.
The upper thread holder function is not used.
[Contents] After trimming, the needle thread is not held.
The upper thread holder function is used.
[Contents] After trimming, the upper thread holder holds the needle thread for the time set at
"
110. ThreadHoleTm.
"
098. ThHold En/Dis
1) DISABLE
2) ENABLE
Setting
Value