158
Function No. : 097
Function Name: Design Call Sensor Time Setting
[Possible when SPS/C-Series I/O Board is used]
This function is to set the time of the design auto call sensor (SEN_0~SEN_3).
Sensor connection method may differ by model types.
10 [Unit 100ms] (default)
[Contents] The sensing time between the first sensor and the next sensor can be set. The basic
unit is 100ms. When "10" is set at the parameter, it means 1000ms or 1 second. This
function is aimed to set the time difference between the sensing acts of different
sensors to ensure accurate sensing.
097. AutoCall TM
10
Setting
Value
Function No. : 096
Function Name: External Control Signal Use Setting
[Possible when SPS/C-Series I/O Board is used]
This function is to use the external input signals to use Sewing Start, Emergency Switch, Clamp and Enter
Key.
The function is disabled (default).
[Contents] When the function is disabled, it is same as the previous usage.
The function is enabled.
[Contents] When the function is enabled, it is possible to use the external input signals to use
Sewing Start, Emergency Switch, Clamp Up/Down, and Enter key.
096. Attatch Set
1) DISABLE
2) ENABLE
Setting
Value
Function No. : 098 Function Name: Upper thread holder setting (C-Series AIR BAG model)
It sets whether to make the upper thread holder hold the needle thread after trimming.
The upper thread holder function is not used.
[Contents] After trimming, the needle thread is not held.
The upper thread holder function is used.
[Contents] After trimming, the upper thread holder holds the needle thread for the time set at
"
110. ThreadHoleTm.
"
098. ThHold En/Dis
1) DISABLE
2) ENABLE
Setting
Value