7
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
INSTALLATION and OPERATION MANUAL
2.4.Electricheangelement/opon/
Allbuffertanksareequippedwith
Outletconnection1½“forelectricheating
element:
3000W/230V;4500W/230V;
6000W/230V;7500W/400V.
The connection of the electric
heating element to the electric
power supply must be done by a
qualified electricians.
When connect the heating
element to the electric network,
make sure that it is properly
grounded.
In the table of technical parameters
is specied locaon for installaon of
electricheangelement.
Buertank
Capacity, L
Connecon Length
L, mm
Current,
W
Voltage,
V
150 ÷ 5000 1
1/2”
210 3000 230
300 ÷ 5000 1
1/2”
320 4500 230
400 ÷ 5000 1
1/2”
410 6000 230
500 ÷ 5000 1
1/2”
590 7500 230/400