SUPA 8
Arming & Disarming
1. How To Disarm
• Enter a valid user code or master code. All the zone lights will flash to show the keypad is waiting for a
key to be pressed.
• Press [0] to disarm the panel.
• The keypad will give a single beep. The On light will go out.
• If any zone lights are flashing then an alarm occurred in that zone.
2. How To Arm
• Close all protected doors and windows, and stop movement in the areas covered by motion detectors.
All the zone lights should be off.
• Enter a valid user code or master code.
• Press [9] to away-arm the panel.
• The keypad will give two beeps. The On light will come on.
• The exit delay will start – leave the protected area.
3. What To Do If Code Does Not Work
• If an invalid code is entered the keypad will give a single long beep.
• Press [∗].
• Re-enter the code.
4. How To Night Arm (Home Arm)
• Close all protected doors and windows, and stop movement in the areas covered by motion detectors.
• Enter a valid user code or master code.
• Press [8] to home-arm the panel.
• The keypad will give two beeps. The On light will flash.
• The exit delay will start – leave the protected area.
5. How To Fully Arm
• To fully arm, after being home-armed, the panel will need to be disarmed and rearmed in the away-arm
mode.
• Enter [User Code] [0] [User Code] [9].
Keypad Functions
6. How To View Memory
• Enter [#] [4]. The On-Line, Low Batt, AC Fail and On lights will all light up.
• Pressing various keys while in review mode will display various events:
1. Displays past zone alarms since last armed.
• The zone lights indicate which zones were tripped. The first zone to be tripped will be
flashing.
2. Displays past alarms other than zones:
• Zone light 1 indicates a duress input has been triggered.
• Zone light 2 indicates a panic input has been triggered.
• Zone light 3 indicates a test input has been triggered.
• Zone light 4 indicates a low battery input has been triggered.
• Zone light 5 indicates an AC fail input has been triggered.
• Zone light 6 indicates an on input has been triggered.
• Zone light 7 indicates a fail to communicate input has been triggered.
3. Displays other previous events:
• Zone light 1 indicates the siren has sounded.
• Zone light 2 indicates the strobe has been on.
• Zone light 3 indicates the dialler has been triggered.
• Zone light 4 indicates the dialler has failed to communicate.
• Zone light 6 indicates that keypad lockout has occurred.
• Zone light 7 indicates a low battery has stopped the siren & strobe.
• Zone light 8 indicates the phone has been answered.
0. Clears all review memories. This also happens when the panel is armed.
7. How To Exit Memory
• If the On-Line, Low Batt, AC Fail and On lights are on, then press [∗] to exit ‘review’ mode.