EasyManua.ls Logo

Superior Fireplaces WRT3036RS - User Manual

Superior Fireplaces WRT3036RS
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
INSTALLATION AND OPERATION INSTRUCTIONS
Superior™ Pro Series Wood burning Fireplaces
MODELS
P/N 126619-01 Rev. D 04/02/15
REPORT NO. 10-078
P126619 01
PFS
®
USC
WRT3036WS
WRT3036WSI
WRT3036WH
WRT3036RS
WRT3036RSI
WRT3036RH
WCT3036WS
WCT3036WSI
WCT3036WH
WCT3036RS
WCT3036RSI
WCT3036RH
SAVE THIS BOOK
This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also
contains information that will enable you to obtain replacement parts or accessory items when needed. Keep
it with your other important papers.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour consultation ultérieure.
This wood burning fireplace complies with UL127
CAN/ULC-S610-M87 standard as a FACTORY
BUILT FIREPLACE.
Ce foyer au bois est conforme aux UL 127 CAN/ULC-
S610-M87 norme comme une USINE CONSTRUITE
CHEMINÉE.
This fireplace is approved for use as a wood burning fireplace or for use with a vented gas log approved to ANSI Z21.60
or Z21.84 standards or for use with a vent-free gas log heater approved to ANSI Z21.11.2 standard.
An INNOVATIVE
HEARTH PRODUCTS, LLC hood must be installed when using a vent-free log heater (see Accessories, page 19).
FOR CANADA: The authority having jurisdiction
(such as the municipal building department, fire
department, etc.) should be contacted before
installation to determine the need to obtain a permit.
POUR LE CANADA: Lautorité compétente (comme le
service municipal du bâtiment, les pompiers, etc.) doit
être contacté avant l’installation afin de déterminer la
nécessité d’obtenir un permis.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
WARNING: If the information in these
instructions is not followed exactly, a fire or
explosion may result causing property damage,
personal injury or death.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou dexplosion ou pour éviter
tout dommage matériel, toute blessure ou la mort.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor’s phone. Follow the gas
supplier’s instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bâtiment
où vous trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
Linstallation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par
le fournisseur de gaz.
Question and Answer IconNeed help?

Do you have a question about the Superior Fireplaces WRT3036RS and is the answer not in the manual?

Overview

This document provides installation and operation instructions for Superior™ Pro Series Wood burning Fireplaces, specifically models WRT3036RS, WCT3036RS, WRT3036RSI, WCT3036RSI, WRT3036RH, WCT3036RH, WRT3036WS, WCT3036WS, WRT3036WSI, WCT3036WSI, WRT3036WH, and WCT3036WH.

Function Description

These fireplaces are designed for burning solid wood fuel. They provide a heat source and can be integrated into residential settings. The units are designed to be installed with a hearth extension and can accommodate optional accessories such as glass doors, double-wall pipe segments, offset and return kits, outside air kits, storm collars, firestop spacers, and roof flashing. Some models are designed for circulating modes, which may include an optional fan/blower kit to enhance heat distribution.

Important Technical Specifications

  • Models: WRT3036RS, WRT3036RSI, WRT3036RH, WCT3036RS, WCT3036RSI, WCT3036RH, WRT3036WS, WRT3036WSI, WRT3036WH, WCT3036WS, WCT3036WSI, WCT3036WH.
  • Minimum Clearances to Combustibles:
    • Back and sides of fireplace: 3/4" minimum*
    • Floor**: 0" minimum
    • Perpendicular wall to opening: 12" minimum
    • Top spacers: 0" minimum
    • Mantel clearances: See Mantels, page 6
    • Chimney outer pipe surface: 1" minimum
    • *Not required at nailing flanges.
    • **See step 2 of Framing.
  • Minimum/Maximum Chimney Height:
    • Minimum height of chimney, measured from base of fireplace to flue gas outlet of termination: 14.5 feet straight flue or 6 feet with two elbow sets.
    • Maximum distance between elbows is 6 feet.
    • Maximum height for any system is 50 feet.
    • Minimum height for two elbow sets, minimum height is 22 feet.
  • Hearth Extension: A hearth extension projecting a minimum of 16" in front of and a minimum of 8" beyond each side of fireplace opening is required. Combustible floor protection is 0" minimum.
  • Combustible Material for Hearth Extension: Thermal conductivity "k" of materials can be obtained from manufacturers or suppliers. Noncombustible materials such as tile, slate, brick, concrete, metal, glass, marble, stone, etc., are suitable.
  • Outside Air Kit (Optional): Models AK4 (sidewall installation) and AK4F (floor installation via vented crawl space) are available. The maximum height for the air vent cannot exceed 3 feet below the flue gas outlet of the termination.
  • Chimney Pipe System: IHP chimney systems consist of 12", 18", 24", 36", and 48" snap-lock, double-wall pipe segments.
  • Firestop Spacers (3600FS-8DM-1): Required at each point where chimney penetrates a floor space to maintain 1" clearance to combustibles.
  • Roof Flashing: Available for 0 to 6/12 pitch roofs (24" base - F0908, 30" base - F0909).
  • Bi-Fold Glass Doors (Optional): Available in 36" standard sizes with black (F0981), brushed brass (F0982), and platinum (F0983) finishes.
  • Anti-Draft Shield: ADS-8DM for round top only (F0927).
  • Mesh Round Top Terminations: RT-8DM, RT-8HT, RTL-8DM, RTL-8HT.
  • Mesh Round Top Terminations with Slip Section: RTT-8DM, RTT-8HT, RTTL-8DM, RTTL-8HT.
  • Round Top Terminations with Louvers: RLT-8DM, RLT-8HT.
  • Round Top Terminations with Louvers w/Slip Section: RLLT-8DM, RLLT-8HT.
  • Square Top Termination with Louvers: ET-8DM, ET-8HT.
  • Square Top Termination with Louvers and Slip Section: ETL-8DM, ETL-8HT.
  • Mesh Square Top Termination: ETO-8DM.
  • Mesh Square Top Termination with Slip Section: ETLO-8DM.
  • Adjustable Hood: Black Fireplace Hood (F1764), Brushed Brass Fireplace Hood (F1766).
  • Fan Kit: BK3 (3-Blade Fan WB & VF only - F1083), BK (Manual Fan, Variable Speed - F1081).
  • Firestop Thimble: 38FST (for penetrating a joist - F0911), FST30 (for offsetting through a joist - F0912).

Usage Features

  • Fuel: Use SOLID WOOD only. Dry and well-seasoned hardwood is recommended. Do NOT use treated wood, charcoal, coal, trash, driftwood, or woods dipped in tar, pitch, pine tar, creosote, or wood products with synthetic binders.
  • Starting a Fire: Never use gasoline, kerosene, charcoal lighter fluid, or similar liquids.
  • Damper: When using a decorative appliance, the fireplace damper must be set in the fully open position.
  • Overfiring: Avoid burning excessive quantities of scrap lumber, pine branches, paper, or cardboard boxes that exceed the volume of a normal log fire. Do not burn trash, chemicals, or chemically treated combustibles, as this can damage the fireplace system and pose hazards.
  • Glass Doors: If equipped, glass doors must be fully opened or fully closed. Never leave them partially open.
  • Outside Air Kit: If installed, ensures adequate air for combustion.
  • Fan/Blower Kit (Optional): For circulating models, enhances heat distribution. Use only IHP manufactured blowers.
  • Carbon Monoxide Poisoning: Burning improper fuel (e.g., charcoal) can lead to carbon monoxide poisoning. Symptoms include headaches, dizziness, or nausea. Ensure adequate ventilation.
  • Smoke Detectors: Recommended in hallways adjacent to the room where the fireplace is installed.

Maintenance Features

  • Ash Disposal: Ashes should be placed in a metal container with a tight-fitting lid and placed on a noncombustible surface, away from combustible materials, until thoroughly cooled.
  • Creosote Removal: When wood is burned slowly, creosote accumulates in the chimney flue. The chimney should be inspected at least twice a year during the heating season. If creosote accumulates to 1/8" (3 mm) or more, it must be removed to reduce the risk of a chimney fire.
  • Chimney Inspection: Inspect the chimney at least twice a year.
  • Cleaning Glass Doors: Use commercial glass cleaner or soap and water. Do not use abrasive material.
  • General Maintenance: Any alteration, service, or maintenance must be performed by a qualified installer or local distributor. Refer to the manual for specific instructions regarding the replacement of parts.
  • Warranty: The product comes with a 20-year limited warranty covering various components, with specific durations for different parts (e.g., 5 years for electrical components, 2 years for refractory and glass). The warranty requires installation by a qualified installer and adherence to local codes.

Superior Fireplaces WRT3036RS Specifications

General IconGeneral
BrandSuperior Fireplaces
ModelWRT3036RS
CategoryIndoor Fireplace
LanguageEnglish