- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Installation and Operation Instructions
Models
CU
S
Report No. F13-094
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900966-02
P/N 900966-00 REV. B 04/2019
DRT3000-C Series Direct-Vent Gas Fireplaces
P900966-00
DRT3040DMN-C
DRT3040DMP-C
DRT3045DEN-C
DRT3045DEP-C
DRT3045DMN-C
DRT3045DMP-C
DRT3035DEN-C
DRT3035DEP-C
DRT3035DMN-C
DRT3035DMP-C
DRT3040DEN-C
DRT3040DEP-C

Questions and Answers

  • C
    Cindy WilsonAug 9, 2025
    Why is pilot burning but no gas to burner on Superior Fireplaces DRT3040DMN-C Indoor Fireplace?
    • M
      Meghan VanceAug 10, 2025
      If the pilot light is on, the valve knob is in the 'ON' position, and the burner switch is also 'ON' but there's no gas to the burner of your Superior Fireplaces Indoor Fireplace, there are several potential causes. First, the wall switch or its wiring might be defective; check connections or try a jumper wire. Second, the thermopile might not be generating enough millivolts; it should read a minimum of 325 millivolts with the switch off. Third, the burner orifice could be plugged, so inspect and clear any blockages. Finally, if using a remote switch, ensure the standard switch is OFF to prevent excessive resistance.
  • A
    Amy McdowellAug 16, 2025
    How to fix spark igniter that won't light pilot on Superior Fireplaces Indoor Fireplace?
    • J
      Joshua HuangAug 16, 2025
      If the spark igniter on your Superior Fireplaces Indoor Fireplace fails to light the pilot after repeated attempts, it could be due to several reasons. First, the igniter itself might be defective; check for a spark at the electrode. If there's no spark and the electrode wire is connected correctly, consider replacing the igniter. Second, the electrode might be misaligned; try lighting the pilot with a match. If it lights, the gas mixture might be the problem. If it still doesn't light, check the gap at the electrode; it should be 1/8 inch. Finally, the gas supply pressure could be incorrect, or the pilot orifice may be blocked; ensure the gas pressure is within the specified limits and clean or replace the pilot orifice.
  • S
    sarahpetersonAug 25, 2025
    What to do if Superior Fireplaces DRT3040DMN-C has frequent pilot/burner outage?
    • K
      kkellyAug 25, 2025
      If you're experiencing frequent pilot/burner outages with your Superior Fireplaces Indoor Fireplace, it might be because the pilot flame is too low or too high, causing the pilot/valve safety to shut off. You should clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermocouple.
  • R
    richard26Sep 1, 2025
    Why pilot will not stay lit on Superior Fireplaces Indoor Fireplace?
    • L
      Lindsey PenningtonSep 1, 2025
      If the pilot light won't stay lit on your Superior Fireplaces Indoor Fireplace, even after following the lighting instructions, the pilot generator (thermocouple) could be defective. Ensure the pilot flame is correctly hitting the thermocouple. Clean and/or adjust the pilot for maximum flame impingement on the thermocouple. Also, make sure the connection between the valve and thermocouple is tight and secure.

Summary

Safety Warnings

Fire and Explosion Hazard Warnings

Critical warnings about fire and explosion risks.

Safety and Your Fireplace

Hot Glass Burn Hazards

Warnings regarding the danger of hot glass and burn risks.

Installation

Installation Preparation and Sequence

Steps for preparing and sequencing the installation process.

Vent System Installation

Instructions for installing vertical and horizontal vent systems.

Vent Termination Clearances

Minimum Clearances to Combustibles

Installation Sequence

Step-by-Step Installation Guide

Detailed sequence of installation steps from framing to finishing.

Vent System Preparation

Electrical Connections

Field Wiring and Grounding Procedures

Instructions for completing field wiring and ensuring proper grounding.

Gas Line Connection

Connecting the Gas Supply Line

Procedures for connecting the gas supply line to the appliance.

Verify Proper Fireplace Operation

Pilot and Burner Operation Checks

Steps to verify proper pilot and burner operation after installation.

Finishing and Flame Appearance

Hood and Barrier Installation

Operation

Installing Logs and Glowing Embers

Installing DRT3000-C 35 Series Log Set

Installing DRT3000-C 40 Series Log Set

Installing DRT3000-C 45 Series Log Set

Glass Door Handling and Safety

Glass Door Installation and Removal

Maintenance Schedule

Lighting Instructions, Millivolt

Millivolt System Lighting Procedures

Step-by-step guide for lighting the millivolt fireplace system.

Lighting Instructions, Electronic

Electronic System Lighting Procedures

Step-by-step guide for lighting the electronic fireplace system.

Troubleshooting

Millivolt System Troubleshooting Guide

Common issues, causes, and solutions for millivolt system problems.

Warranty Information

Superior Fireplaces DRT3040DMN-C Specifications

General IconGeneral
CategoryIndoor Fireplace
ModelDRT3040DMN-C
TypeDirect Vent
Fuel TypeNatural Gas
IgnitionElectronic Ignition
FinishBlack
VentingDirect Vent

Related product manuals