- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Installation and Operation Instructions
Models
CU
S
Report No. F13-094
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900966-02
P/N 900966-00 REV. B 04/2019
DRT3000-C Series Direct-Vent Gas Fireplaces
P900966-00
DRT3040DMN-C
DRT3040DMP-C
DRT3045DEN-C
DRT3045DEP-C
DRT3045DMN-C
DRT3045DMP-C
DRT3035DEN-C
DRT3035DEP-C
DRT3035DMN-C
DRT3035DMP-C
DRT3040DEN-C
DRT3040DEP-C

Questions and Answers

  • C
    Christopher SanchezAug 3, 2025
    Why is pilot burning but no gas to burner on Superior Fireplaces Indoor Fireplace?
    • D
      Denise ColonAug 4, 2025
      If the pilot light is on, the valve knob is in the 'ON' position, and the burner switch is also 'ON' but there's no gas to the burner of your Superior Fireplaces Indoor Fireplace, there are several potential causes. First, the wall switch or its wiring might be defective; check connections or try a jumper wire. Second, the thermopile might not be generating enough millivolts; it should read a minimum of 325 millivolts with the switch off. Third, the burner orifice could be plugged, so inspect and clear any blockages. Finally, if using a remote switch, ensure the standard switch is OFF to prevent excessive resistance.
  • M
    markfarmerAug 11, 2025
    How to fix spark igniter that won't light pilot on Superior Fireplaces DRT3035DEN-C?
    • T
      Tara JohnsonAug 11, 2025
      If the spark igniter on your Superior Fireplaces Indoor Fireplace fails to light the pilot after repeated attempts, it could be due to several reasons. First, the igniter itself might be defective; check for a spark at the electrode. If there's no spark and the electrode wire is connected correctly, consider replacing the igniter. Second, the electrode might be misaligned; try lighting the pilot with a match. If it lights, the gas mixture might be the problem. If it still doesn't light, check the gap at the electrode; it should be 1/8 inch. Finally, the gas supply pressure could be incorrect, or the pilot orifice may be blocked; ensure the gas pressure is within the specified limits and clean or replace the pilot orifice.
  • O
    orrmelissaAug 19, 2025
    What to do if Superior Fireplaces Indoor Fireplace has frequent pilot/burner outage?
    • Y
      youngtylerSep 12, 2025
      If you're experiencing frequent pilot/burner outages with your Superior Fireplaces Indoor Fireplace, it might be because the pilot flame is too low or too high, causing the pilot/valve safety to shut off. You should clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermocouple.
  • C
    Cindy JacksonAug 26, 2025
    Why pilot will not stay lit on Superior Fireplaces DRT3035DEN-C?
    • J
      Jenny DunlapAug 26, 2025
      If the pilot light won't stay lit on your Superior Fireplaces Indoor Fireplace, even after following the lighting instructions, the pilot generator (thermocouple) could be defective. Ensure the pilot flame is correctly hitting the thermocouple. Clean and/or adjust the pilot for maximum flame impingement on the thermocouple. Also, make sure the connection between the valve and thermocouple is tight and secure.

Summary

Safety and General Information

Safety and Your Fireplace

Covers essential safety guidelines and warnings for operating the fireplace safely.

Important Safety Information

Detailed safety precautions, warnings, and recommendations for safe use and handling.

Appliance Operation Notices

Important notices regarding appliance operation, fuel types, and safety considerations.

Installation Procedures

Codes and Standards

Outlines the codes, standards, and regulations applicable to fireplace installation.

Vent Termination Clearances

Specifies minimum clearances for vertical and horizontal vent terminations.

Minimum Clearances to Combustibles

Details required clearances from combustible materials around the fireplace and vent system.

Installation Sequence

Step-by-step guide for the complete installation process of the fireplace.

Gas Conversion Kits

Information on kits and procedures for converting the fireplace between gas types.

Appliance Operation

Burn-in Period

Guidelines for the initial operation period, including expected odors and cleaning.

Install the Logs and Glowing Embers

Instructions for correctly installing the decorative logs and glowing embers.

Installing and removing the glass door

Procedures for safely installing and removing the fireplace glass door.

Lighting Instructions, Millivolt - English

Step-by-step instructions for lighting millivolt ignition systems in English.

Maintenance and Troubleshooting

Maintenance Schedule

A schedule detailing required maintenance tasks, frequency, and responsible parties.

Accessory Components

Lists available accessory components for the fireplace, such as liners and kits.

Troubleshooting Millivolt Systems

Guide to diagnosing and resolving common issues with millivolt ignition systems.

Parts and Warranty

Replacement Parts

Identifies and lists available replacement parts for the fireplace.

The Warranty

Details the warranty coverage, terms, exclusions, and limitations for the product.

Superior Fireplaces DRT3035DEN-C Specifications

General IconGeneral
CategoryIndoor Fireplace
ModelDRT3035DEN-C
TypeDirect Vent Gas Fireplace
Fuel TypeNatural Gas or Propane
EfficiencyUp to 70%
Firebox MaterialSteel
Ignition TypeElectronic Ignition
VentingDirect Vent

Related product manuals