- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Installation and Operation Instructions
Models
CU
S
Report No. F13-094
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900948-02
P/N 900948-00 REV. C 06/2019
DRT2000-C Series Direct-Vent Gas Fireplaces
P900948-00
DRT2040REN-C
DRT2040REP-C
DRT2040RMN-C
DRT2040RMP-C
DRT2040TEN-C
DRT2040TEP-C
DRT2040TMN-C
DRT2040TMP-C
DRT2035REN-C
DRT2035REP-C
DRT2035RMN-C
DRT2035RMP-C
DRT2035TEN-C
DRT2035TEP-C
DRT2035TMN-C
DRT2035TMP-C
DRT2045DEN-C
DRT2045DEP-C
DRT2045DMN-C
DRT2045DMP-C

Other manuals for Superior Fireplaces DRT2000-C Series

Questions and Answers

  • K
    Kimberly PooleAug 12, 2025
    Why is pilot burning but no gas to burner on Superior Fireplaces DRT2000-C?
    • S
      Steven JohnsonAug 12, 2025
      If the pilot light is on, the valve knob is in the 'ON' position, and the burner switch is also 'ON' but there's no gas to the burner of your Superior Fireplaces Indoor Fireplace, there are several potential causes. First, the wall switch or its wiring might be defective; check connections or try a jumper wire. Second, the thermopile might not be generating enough millivolts; it should read a minimum of 325 millivolts with the switch off. Third, the burner orifice could be plugged, so inspect and clear any blockages. Finally, if using a remote switch, ensure the standard switch is OFF to prevent excessive resistance.
  • S
    Stephanie NelsonAug 16, 2025
    How to fix spark igniter that won't light pilot on Superior Fireplaces DRT2000-C Indoor Fireplace?
    • L
      Linda MillsAug 16, 2025
      If the spark igniter on your Superior Fireplaces Indoor Fireplace fails to light the pilot after repeated attempts, it could be due to several reasons. First, the igniter itself might be defective; check for a spark at the electrode. If there's no spark and the electrode wire is connected correctly, consider replacing the igniter. Second, the electrode might be misaligned; try lighting the pilot with a match. If it lights, the gas mixture might be the problem. If it still doesn't light, check the gap at the electrode; it should be 1/8 inch. Finally, the gas supply pressure could be incorrect, or the pilot orifice may be blocked; ensure the gas pressure is within the specified limits and clean or replace the pilot orifice.
  • R
    roliverAug 23, 2025
    Why pilot will not stay lit on Superior Fireplaces Indoor Fireplace?
    • M
      Marcus RochaAug 23, 2025
      If the pilot light won't stay lit on your Superior Fireplaces Indoor Fireplace, even after following the lighting instructions, the pilot generator (thermocouple) could be defective. Ensure the pilot flame is correctly hitting the thermocouple. Clean and/or adjust the pilot for maximum flame impingement on the thermocouple. Also, make sure the connection between the valve and thermocouple is tight and secure.
  • S
    Shelley HaynesAug 27, 2025
    Why won't the pilot light stay lit on my Superior Fireplaces Indoor Fireplace?
    • S
      Stephen GreenAug 27, 2025
      If the pilot light on your Superior Fireplaces Indoor Fireplace won't stay lit, make sure the pilot flame is hitting the thermocouple. You may need to clean and adjust the pilot for better flame contact. Also, check that the connection between the valve and thermocouple is tight and secure.
  • K
    Kevin GravesAug 31, 2025
    How to fix a spark igniter that won't light the pilot on my Superior Fireplaces Indoor Fireplace?
    • N
      Nathan RogersAug 31, 2025
      If the spark igniter on your Superior Fireplaces Indoor Fireplace isn't lighting the pilot, first check for a spark at the electrode and pilot. If there's no spark and the electrode wire is connected correctly, the igniter may be defective and need replacement. If there is a spark, try lighting the pilot with a match. If it lights, the gas mixture might be off, so allow for a longer purge. If it still doesn't light, check the gap at the electrode and pilot; it should be 1/8 inch for a strong spark. If the gap is correct, the pilot might need replacing. Also, check the inlet gas pressure to ensure it's within the limits marked on the rating plate, and inspect the pilot orifice for any blockages, cleaning or replacing it if necessary.
  • D
    David GravesSep 7, 2025
    Why does my Superior Fireplaces Indoor Fireplace frequently have pilot/burner outages?
    • L
      lauren28Sep 7, 2025
      If you're experiencing frequent pilot/burner outages with your Superior Fireplaces Indoor Fireplace, the pilot flame might be too low or too high, causing the pilot/valve safety to shut off. Try cleaning and adjusting the pilot flame to ensure it properly impinges on the thermocouple.
  • M
    mendezloganSep 10, 2025
    What to do if Superior Fireplaces DRT2000-C Indoor Fireplace has frequent pilot/burner outage?
    • S
      Sherry EatonSep 12, 2025
      If you're experiencing frequent pilot/burner outages with your Superior Fireplaces Indoor Fireplace, it might be because the pilot flame is too low or too high, causing the pilot/valve safety to shut off. You should clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermocouple.

Superior Fireplaces DRT2000-C Series Specifications

General IconGeneral
BrandSuperior Fireplaces
ModelDRT2000-C Series
CategoryIndoor Fireplace
LanguageEnglish