- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Installation and Operation Instructions
Models
CUS
Report No. F13-094
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900684-05.
P/N 900684-01 REV. C 06/2018
DRT3000 Series Direct-Vent Gas Fireplaces
DRT3033TMN
DRT3033TMP
DRT3033TEN-B
DRT3033TEP-B
DRT3033RMN
DRT3033RMP
DRT3033REN-B
DRT3033REP-B
DRT3035DMN
DRT3035DMP
DRT3035DEN-B
DRT3035DEP-B
DRT3040DMN
DRT3040DMP
DRT3040DEN-B
DRT3040DEP-B
DRT3045DMN
DRT3045DMP
DRT3045DEN-B
DRT3045DEP-B
P900684-01

Table of Contents

Questions and Answers

  • W
    woodsallisonAug 15, 2025
    What to do if my Superior Fireplaces DRT3033TEN-B is not turning on or off?
    • T
      Tyler LyonsAug 15, 2025
      If your Superior Fireplaces Indoor Fireplace isn't turning on or off, first ensure the wall switch plate is set to REMOTE. Then, check the gas supply and shutoff valves to confirm gas is reaching the fireplace. Finally, check or replace the backup batteries behind the wall plate to ensure the unit is receiving power.
  • M
    Megan ShahAug 18, 2025
    How to fix a Superior Fireplaces DRT3033TEN-B spark igniter that won't light the pilot?
    • H
      Hailey MolinaAug 18, 2025
      If the pilot light won't ignite on your Superior Fireplaces Indoor Fireplace after repeatedly pressing the igniter button, check for a spark at the electrode and pilot. If there's no spark and the electrode wire is connected properly, replace the igniter. Also, verify that the inlet gas pressure is within the limits marked on the rating plate. Finally, clean or replace the pilot orifice if it's plugged.
  • K
    Karen HahnAug 21, 2025
    Why does my Superior Fireplaces DRT3033TEN-B Indoor Fireplace main burner light then go out?
    • K
      kristinaparksAug 21, 2025
      If the main burner of your Superior Fireplaces Indoor Fireplace lights but then goes out, start by checking the gas supply and shutoff valves. Next, inspect the control compartment for any loose wiring to the valve or ignition module, consulting a service technician if needed. Since pilot flame is not engulfing the sensor or there is obstructed vent system you should call a service technician.
  • M
    michaeltorresAug 26, 2025
    What to do if the main burner on my Superior Fireplaces Indoor Fireplace won't light?
    • K
      Kenneth BakerAug 26, 2025
      If the main burner on your Superior Fireplaces Indoor Fireplace doesn't light but the igniter is sparking, first check the gas supply and shutoff valves to ensure gas is reaching the unit. Inspect the control compartment for any loose wiring to the valve and ignition module, consulting a service technician if necessary. If there is air in the gas line you should call a service technician. Finally, replace the unit's battery backup.
  • R
    Rodney WilliamsAug 28, 2025
    Why won't the pilot light stay lit on my Superior Fireplaces Indoor Fireplace?
    • B
      Brandi MossAug 28, 2025
      If your Superior Fireplaces Indoor Fireplace pilot light won't stay lit after following the lighting instructions, ensure the pilot flame is correctly impinging on the thermocouple. Clean and/or adjust the pilot for maximum flame impingement on the thermocouple. Also, verify that the connection between the valve and thermocouple is tight and secure.
  • D
    David NicholsSep 4, 2025
    How to stop frequent pilot/burner outages in my Superior Fireplaces DRT3033TEN-B?
    • M
      mlewisSep 4, 2025
      If you're experiencing frequent pilot/burner outages with your Superior Fireplaces Indoor Fireplace, the pilot flame may be too low or too high, causing the pilot/valve safety to drop out. To resolve this, clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermocouple.
  • I
    ihallSep 7, 2025
    Why is there soot on the logs and glass of my Superior Fireplaces DRT3033TEN-B Indoor Fireplace?
    • A
      Alexander EvansSep 7, 2025
      If you notice soot on the logs and glass of your Superior Fireplaces Indoor Fireplace, ensure the logs are properly positioned as detailed on Page 55. If it's initial fireplace operation, a white film may develop on the glass during the first few fires as part of the burn-in process. Clean the glass after each use (AFTER THE GLASS HAS COMPLETELY COOLED). Also, check for Improper vent restrictor setting and improper air shutter opening.
  • J
    jbentleySep 12, 2025
    How to fix poor or blue flame in Superior Fireplaces DRT3033TEN-B Indoor Fireplace?
    • C
      Cassandra PierceSep 12, 2025
      If your Superior Fireplaces Indoor Fireplace has a poor flame or a blue flame, the door seal may not be properly aligned, causing gaps and air leaks. Remove and realign the door to ensure the gasket seal is fully engaged around the door frame.
  • V
    vrubioDec 1, 2025
    Why is my Superior Fireplaces Indoor Fireplace pilot burning but no gas to burner?
    • J
      jennifer49Dec 1, 2025
      If your Superior Fireplaces Indoor Fireplace pilot is burning but no gas is reaching the burner, check the wall switch and its wiring for proper connections. If the burner comes on after using a jumper wire across the terminals at the wall switch, replace the defective switch. If the switch is okay, but the burner comes on when you jumper the wires at the valve, the wires are faulty or connections are bad. Also, check the burner orifice for blockage and remove any obstructions. When turning on the burner using a *remote switch, ensure that the standard OFF/ON switch is in the OFF position. If both switches are in the ON position, it may result in excessive resistance (and millivolt drainage) and the burner may not come on. Finally, check the thermopile with a millivolt meter at the gas val...

Superior Fireplaces DRT3033TEN-B Specifications

General IconGeneral
CategoryIndoor Fireplace
BrandSuperior Fireplaces
ModelDRT3033TEN-B
TypeDirect Vent Gas Fireplace
Fuel TypeNatural Gas
EfficiencyUp to 80%
VentingDirect Vent