- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Installation and Operation Instructions
Models
CUS
Report No. F13-094
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900684-05.
P/N 900684-01 REV. C 06/2018
DRT3000 Series Direct-Vent Gas Fireplaces
DRT3033TMN
DRT3033TMP
DRT3033TEN-B
DRT3033TEP-B
DRT3033RMN
DRT3033RMP
DRT3033REN-B
DRT3033REP-B
DRT3035DMN
DRT3035DMP
DRT3035DEN-B
DRT3035DEP-B
DRT3040DMN
DRT3040DMP
DRT3040DEN-B
DRT3040DEP-B
DRT3045DMN
DRT3045DMP
DRT3045DEN-B
DRT3045DEP-B
P900684-01

Table of Contents

Questions and Answers

  • R
    Rachel GrayAug 21, 2025
    Why won't the pilot light stay lit on my Superior Fireplaces DRT3000?
    • C
      carlsonmichaelAug 21, 2025
      If your Superior Fireplaces Indoor Fireplace pilot won't stay lit after following the lighting instructions, the pilot generator (thermocouple) may be defective. Ensure the pilot flame is directly hitting the thermocouple. You may need to clean and/or adjust the pilot for maximum flame impingement on the thermocouple. Also, verify that the connection between the valve and thermocouple is tight and secure.
  • W
    wrichardsonAug 26, 2025
    Why does my Superior Fireplaces DRT3000 have frequent pilot/burner outages?
    • P
      peterhickmanAug 26, 2025
      If you're experiencing frequent pilot/burner outages with your Superior Fireplaces Indoor Fireplace, the pilot flame may be too low or too high, causing the pilot/valve safety to shut off. To fix this, clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermocouple.
  • S
    sheilawarrenAug 28, 2025
    What to do if nothing happens when turning ON/OFF my Superior Fireplaces DRT3000 Indoor Fireplace?
    • C
      charlesyoungAug 28, 2025
      If nothing happens when you turn your Superior Fireplaces Indoor Fireplace ON or OFF, consider the following: * The remote may not be working right. Make sure the wall switch plate is set to REMOTE. * Gas might not be reaching the fireplace. Check the gas supply and gas shutoff valves. * The unit might not be getting power. Check or replace the backup batteries behind the wall plate.
  • U
    uhowardAug 30, 2025
    Why won't the main burner light on my Superior Fireplaces DRT3000 Indoor Fireplace, even though the igniter is sparking?
    • N
      Nicholas SanchezAug 30, 2025
      If the main burner of your Superior Fireplaces Indoor Fireplace doesn't light, even though the igniter is sparking, it could be due to several reasons. First, check that the gas supply and shutoff valves are open and that gas is reaching the fireplace. Also, inspect the control compartment for any loose wiring to the valve or ignition module; if you find any, it's best to call a service technician. Another potential issue is air in the gas line, which might require purging by a service technician. Finally, make sure the unit is receiving power by replacing the unit's battery backup.
  • J
    Jessica MyersSep 1, 2025
    What to do if the main burner on my Superior Fireplaces DRT3000 comes on but then goes out?
    • J
      Jay DelgadoSep 1, 2025
      If the main burner of your Superior Fireplaces Indoor Fireplace comes on but then goes out, it could be due to several reasons. Check that the gas supply and shutoff valves are open and that gas is reaching the fireplace. Inspect the control compartment for any loose wiring to the valve or ignition module; if found, it's best to call a service technician. If the pilot flame is not engulfing the sensor or if the vent system is obstructed, you should also call a service technician.
  • U
    usanfordSep 3, 2025
    Why is there soot on the logs and glass of my Superior Fireplaces DRT3000 Indoor Fireplace?
    • M
      Megan FryeSep 3, 2025
      If you notice soot on the logs and glass of your Superior Fireplaces Indoor Fireplace, there are several possible causes. Excessive flame impingement on the logs could be the issue, so ensure they are properly positioned. A white film may develop on the glass during the first few uses as part of the burn-in process. Clean the glass after each use (AFTER THE GLASS HAS COMPLETELY COOLED). Also, check for an improper vent restrictor setting or air shutter opening, and adjust them according to the instructions.
  • A
    Alyssa Phelps MDSep 5, 2025
    What to do if my Superior Fireplaces DRT3000 is not turning on or off?
    • P
      parkermeganSep 5, 2025
      If your Superior Fireplaces Indoor Fireplace isn't turning on or off, first ensure the wall switch plate is set to REMOTE. Then, check the gas supply and shutoff valves to confirm gas is reaching the fireplace. Finally, check or replace the backup batteries behind the wall plate to ensure the unit is receiving power.
  • A
    angel52Sep 7, 2025
    Why does my Superior Fireplaces DRT3000 Indoor Fireplace main burner light then go out?
    • B
      Barbara McgeeSep 7, 2025
      If the main burner of your Superior Fireplaces Indoor Fireplace lights but then goes out, start by checking the gas supply and shutoff valves. Next, inspect the control compartment for any loose wiring to the valve or ignition module, consulting a service technician if needed. Since pilot flame is not engulfing the sensor or there is obstructed vent system you should call a service technician.
  • J
    Jacob PollardSep 9, 2025
    What to do if the main burner on my Superior Fireplaces DRT3000 won't light?
    • H
      heatonSep 10, 2025
      If the main burner on your Superior Fireplaces Indoor Fireplace doesn't light but the igniter is sparking, first check the gas supply and shutoff valves to ensure gas is reaching the unit. Inspect the control compartment for any loose wiring to the valve and ignition module, consulting a service technician if necessary. If there is air in the gas line you should call a service technician. Finally, replace the unit's battery backup.
  • C
    carolinelewisSep 14, 2025
    How to stop frequent pilot/burner outages in my Superior Fireplaces DRT3000?
    • S
      Stephanie GreenSep 14, 2025
      If you're experiencing frequent pilot/burner outages with your Superior Fireplaces Indoor Fireplace, the pilot flame may be too low or too high, causing the pilot/valve safety to drop out. To resolve this, clean and/or adjust the pilot flame to ensure maximum flame impingement on the thermocouple.