PROBLEM:
When valve is closed, water is weeping
past the valve and coming out the lowest
head.
CAUSE:
Small debris in seat disc, or pitted seat disc
that is allowing water to seep by.
SOLUTION:
Remove adaptor from valve body and
clean debris. If seat disc is pitted, remove
seat disc, flip it over and reassemble onto
shaft or replace seat disc.
PROBLEM:
Water leaks out of top of adaptor where flow
control stem protrudes from top housing.
CAUSE:
Damaged flow-control o-ring.
SOLUTION:
Turn flow-control handle clockwise as many
turns as possible. Next, remove nut and flow-
control handle then unscrew flow-control
stem from underside of bonnet. Replace flow-
control o-ring. Apply silicone grease to o-ring
before reassembling it to bonnet.
13
13
Troubleshooting