For Superior's
Gas Insert
Models
61-3821 N
GI-3821 P
GI-3821 NB
GI-3821 PB
GI-3821 NX
GI-3821 PX
For Use With Superior's
Factory-Built Fireplace
Models
Also For
1Jse
With
Solid Fuel Burning
Mzsonry Fireplaces
Fith Opei7irig Widths
From
31"
To 46"
And Opening Heights
From
21"
To
31"
And Any Other
Solid Fuel Burning
Factory-Built Fireplace
With Minimum Open Width
Of
30%"
And Minimum Height
Of
20%"
11
1
warning:
If
the information in
fll
this manual is not followed ex-
actly, a fire or explosion may
-
Do not store or use gasoline or
otherflammablevapors and liq-
uids in the vicinity
of
this or any
other appliance.
I
I
-
WHATTO
DO
IFYOU SMELLGAS
I
I
Do nottryto lightany appliance.
Do not touch any electrical
switch.
Do not use any phone in your
building.
Immediately call your gas sup-
plier from
a
neighbor's phone.
Followthe
gassupplier's Instruc-
tions.
If
you cannotreachyourgassup-
plier, call the fire department.
-
Insfallation and service must be
performed by a qualified in-
staller, service agency or the
gas supplier.
Due to
high
temperatures, the appliance
should be located out
ol tralfic and away
from furniture or draperies.
Do
not
place clothing or other materials
on or near this appliance.
PLEASE
RETAIN
THIS
MANUAL
FOR
FUTURE
REFERENCE.
Question and Answer IconNeed help?

Do you have a question about the Superior GI-3821N and is the answer not in the manual?

Summary

INTRODUCTION

TYPICAL INSTALLATION

Illustrates various installation configurations for the gas insert.

SAFETY PRECAUTIONS

INSTALLATION OPTIONS

Factory-Built Fireplace Installation Overview

Details installation within Superior's factory-built fireplace systems.

Masonry Fireplace Installation Overview

Details installation into traditional masonry fireplaces with specific requirements.

Optional Masonry Fireplace Installation Overview

Describes an alternative installation for masonry fireplaces without a damper.

FACTORY-BUILT FIREPLACE PREPARATION

INSTALLING THE GAS INSERT

Fireplace Modification Steps

Sequential steps for modifying the fireplace structure prior to insert installation.

Modification Procedures

Detailed steps for altering fireplace components for insert compatibility.

Vertical Termination Systems (Roof)

Explains vertical venting configurations terminating through the roof.

Prepare Gas Insert for Installation

Modify the Existing Firebox

Route Vent Ducting

Position Gas Insert within the Firebox

Installing the Optional Blower

Connecting Gas Line

High Elevation Derating

Log Installation

FLAME APPEARANCE AND SOOTING

ADJUSTMENT

OPTIONAL EQUIPMENT

Forced Air Kits

Information on the GIB-1600 forced air blower kit installation.

43 Side Panel Conversion Kit

Kit for adapting the insert to 43-inch wide firebox openings.

Brass Louver Kit

Aesthetic enhancement with a brass-tone aluminum louver kit.

Arch Door Trim

Decorative brass-tone aluminum trim for the appliance door.

Gas Flex Line with Valve

Brick Panel Kit

Masonry Surround Kits

Gas Conversion Kits

Maintenance

Gasket Inspection

Procedure for inspecting the glass enclosure panel gasket for integrity.

WARRANTY

REPLACEMENT PARTS

ACCESSORIES AND COMPONENTS

GAS INSERT SPECIFICATIONS

TROUBLESHOOTING THE GAS CONTROL SYSTEM

LIGHTING INSTRUCTIONS

Summary

INTRODUCTION

TYPICAL INSTALLATION

Illustrates various installation configurations for the gas insert.

SAFETY PRECAUTIONS

INSTALLATION OPTIONS

Factory-Built Fireplace Installation Overview

Details installation within Superior's factory-built fireplace systems.

Masonry Fireplace Installation Overview

Details installation into traditional masonry fireplaces with specific requirements.

Optional Masonry Fireplace Installation Overview

Describes an alternative installation for masonry fireplaces without a damper.

FACTORY-BUILT FIREPLACE PREPARATION

INSTALLING THE GAS INSERT

Fireplace Modification Steps

Sequential steps for modifying the fireplace structure prior to insert installation.

Modification Procedures

Detailed steps for altering fireplace components for insert compatibility.

Vertical Termination Systems (Roof)

Explains vertical venting configurations terminating through the roof.

Prepare Gas Insert for Installation

Modify the Existing Firebox

Route Vent Ducting

Position Gas Insert within the Firebox

Installing the Optional Blower

Connecting Gas Line

High Elevation Derating

Log Installation

FLAME APPEARANCE AND SOOTING

ADJUSTMENT

OPTIONAL EQUIPMENT

Forced Air Kits

Information on the GIB-1600 forced air blower kit installation.

43 Side Panel Conversion Kit

Kit for adapting the insert to 43-inch wide firebox openings.

Brass Louver Kit

Aesthetic enhancement with a brass-tone aluminum louver kit.

Arch Door Trim

Decorative brass-tone aluminum trim for the appliance door.

Gas Flex Line with Valve

Brick Panel Kit

Masonry Surround Kits

Gas Conversion Kits

Maintenance

Gasket Inspection

Procedure for inspecting the glass enclosure panel gasket for integrity.