11
NOTE: Be certain that the flange nuts are tightened against the surface of the air cleaner.
NOTE: When suspending the air cleaner from the ceiling or other overhead support, use
steel s-hooks that are a minimum of 5/16".
NOTE: Thread all lag hooks at least 1-1/2" into the supporting structural members.
Never secure the air cleaner hardware to drywall, drop ceiling tile/frame,
or other non-structural members.
Keep a minimum of seven feet between bottom of air cleaner and the
floor surface.
Do not use rope, cable or power cord to suspend the unit from the ceiling.
Use chain rated for a minimum of a 150 lb. working load.
IMPORTANT: When determining a location to mount the unit, the air cleaner will
operate more efficiently when the air flow is unrestricted. Do not locate the unit in a
corner or near any heating or cooling vents.