Super X13SCW-F User's Manual
4
NIC1/NIC2 (LAN1/LAN2)
The Network Interface Controller (NIC) LED connection for LAN port 1 is located on pins
11 and 12 of JF1, and LAN port 2 is on pins 9 and 10. Attach the NIC LED cables here to
display network activity. Refer to the table below for pin denitions.
Power Button
UID LED
NIC1 Active LED
Reset Button
HDD LED
PWR LED
Reset
PWR
UID SW
3.3V Stby
Ground
19
X
Ground
X
3.3V Stby
20
1 2
Ground
Power Fail LED
NIC2 Active LED
NMI
3.3V
3.3V
OH/Fan Fail LED
1. NIC2 LED
2. NIC1 LED
3. UID Switch
4. HDD LED
1
2
3
LAN1/LAN2 LED
Pin Denitions (JF1)
Pins Denition
9 VCC
10 NIC2 Link/Active LED
11 VCC
12 NIC1 Link/Active LED
HDD LED/UID Switch
The HDD LED/UID Switch connection is located on pins 13 and 14 of JF1. Attach a cable
to pin 14 to show hard drive activity status. Attach a cable to pin 13 to use the UID switch.
Refer to the table below for pin denitions.
HDD LED/UID Switch
Pin Denitions (JF1)
Pin# Denition
13 3.3 V Stdby/UID SW
14 HDD Active