EasyManua.ls Logo

Sure Flame SL11B - Specifications

Default Icon
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SL11B & S1500 Manual 934-6644 - Page 6
SPECIFICATIONS
SL11B & S1500 Construction Heaters
Certified to CSA 2.14-2000 Gas Fired Unvented Construction Heater
Gases: Natural or Propane
Capacity: SL11B 1,000,000 Btu/h
S1500 1,500,000 Btu/h Maximum
850,000 Btu/h Minimum
Orifice Size: 43 DMS x 46)
Blower: 7,000 cfm
Electrical Rating: 115 volts, 60 Hz, 15 amps, single phase
Gas Supply: SL11B
Inlet Pressure Manifold Pressure
Max.W.C. Min.W.C. Max.W.C.
Propane 14 inch 8 inch 1.8 inch
Natural 14 inch 8 inch 4.8 inch
(Minimum inlet pressure is for purpose of input adjustment)
Gas Supply: S1500
Inlet Pressure Manifold Pressure
Max.W.C. Min.W.C. Max.W.C. Min.W.C
Propane 14 inch 8 inch 2.7 inch 0.75 inch
Natural 14 inch 8 inch 7.2 inch 2.0 inch